4. Battery
General
o Charge the battery before use. The recharging time of an empty battery is about 7 hours. The
temperature of the battery to be recharged must be +10...+ 30 C.
o Recharging should always take place at a room temperature of about +20 C, in a dry place shielded
from dust and direct sunlight.
o The recharger
performs a battery test at start of each charging to detect defective batteries.
o Optimum performance with new battery packs is achieved only after they have completed three
charge-cycles.
Note!
o A new battery or a battery stored for a longer period or an over-discharged battery may not
function stably, which will terminate the recharging prematurely. Monitor the red signal light
(=charging in operation) after e.g. 30 or 60 minutes and initiate the recharging several times if
needed.
o In too cold/warm an environment the battery will not be charged.
o Never recharge in a potentially explosive environment!
o When not in use, prevent over-discharge of battery by keeping the blower device always on
recharge. Overcharging of battery is automatically prevented.
Recharging
Connect the recharging device to the main power supply (100-240 V/ 50 Hz). When not connected
to the blower device, the signal light will not start burning.

Push the recharging plug into the charging connector and turn the plug slightly clockwise until it sits
fast, otherwise the battery will not be charged. The charging will start automatically.
o  red signal light remains on. The time needed depends
on the battery status.
o Recharging is complete when the red signal light goes out, and the green signal light starts burning
and stays on (standby level).
o The recharging plug will come off when you pull the locking and simultaneously turn the plug
counter-clockwise. Then close the protective lid.
Signal lights on the recharging device
Red light on:
= Charging in operation.
Green light on:
= Battery fully charged (standby charge).
Red light blinking::
= Wrong or defective battery.