3. Selection
Promask/Promask
2
+ filter
Breathing protector equipped with filter
Type of protective device
Multiples of threshold concentration **)
Remarks, limitations
APF (Assigned protection factor)
BS 4275 (GB)
BGR 190-ZH1/701 (DE)
Full face mask with particle filter P3
40
400
Particles
Full face mask with gas filter *)
20
400
Filter types A, B, E, K, AX, SX, Hg-P3 and
NO-P3 have different applications. For more
information, see Instructions for Use of Scott
Health & Safety filters.
Device with combined filter
The specified multiples of threshold value for the gas or particle
filters are given separately, but in all cases the lowest value applies
*) Provided that the maximum permissible detrimental gas concentration for the gas filter is not exceeded.
For non-powered filtering devices with gas filter, concentration must not exceed 0.1 vol.% in gas filter
class 1 and 0.5 vol.% in gas filter class 2 and 1.0 vol.% in gas filter class 3.
**) If national guidelines exist: in all cases the lowest value applies.
Promask + blower device
Blower-assisted breathing protector equipped with filter
Type of protective device
Multiples of threshold concentration **)
Remarks, limitations
APF (Assigned protection factor)
BS 4275 (GB)
BGR 190-ZH1/701 (DE)
Power-assisted full face mask with
particle filter TM3P
40
500
Power-assisted full face mask with
gas filter *)
TM3 gas filter class 1, 2 or 3
40
500
For devices with combined filter apply the
relevant limitations of gas and particle filters.
Device with combined filter
The specified multiples of threshold value for the gas or particle
filters are given separately, but in all cases the lowest value applies.
*) Provided that the maximum permissible detrimental gas concentration for the gas filter is not exceeded.
For power-assisted filtering devices with gas filter, concentration must not exceed 0.05 vol.% in gas filter
class 1 and 0.1 vol.% in gas filter class 2 and 0.5 vol.% in gas filter class 3.
**) If national guidelines exist: in all cases the lowest value applies.
4. Preparations for use, and Donning
See Instructions for Use of the filter and blower device to be used.
Check before use
intactness of facepiece, rubber parts and visor
head harness condition and elasticity
that speech diaphragm is in place
that exhalation valve is in place and that its cover is properly fastened
that inh. and exh. valves function properly
that the filter is correct for the intended use. Filter type and class are evident from the
marking.
that storage period of the filter has not been exceeded
filter condition and intactness. Shake the filter to ensure that there are no loose
components/contents. The filter shall be replaced if it has been exposed to excessive force
or impact. It may be damaged.
With a blower device
Check adequate air flow (see Instructions for Use of the blower unit).