Installation Instructions & User Guide
Thermostatic Recessed Dual Control Shower Valve
Models Covered: NU-022 / NU-023 / NU-024
NU-028 / NU-029 / NU-030
IMPORTANT: Please keep these instructions for future reference.

Questions and Answers

  • K
    kthompsonAug 9, 2025
    What to do if SCUDO Control Unit provides only hot or cold water?
    • C
      Chris ArcherAug 9, 2025
      If you're only getting hot or cold water from your SCUDO Control Unit shower valve, first, make sure the stop or service valve in the water supply pipework is fully open. Next, check the inlet filter for any blockages, cleaning or replacing it as necessary and flush the pipework. Finally, verify that the hot and cold water supplies aren't reversed, ensuring the hot is on the left and the cold is on the right when viewed from the front, and rework the pipework if needed.
  • J
    jerrygarciaAug 15, 2025
    Why is the outlet water temperature too hot or cold in SCUDO NU-022 Control Unit?
    • M
      Mr. John WhiteAug 15, 2025
      If the outlet water temperature from the SCUDO Control Unit is too hot or cold, start by checking the inlet filters for any blockages and clean them if necessary. Also, verify that the installation conditions are within the specified operating parameters. Consider servicing the shower valve as recommended, referring to the Maintenance and Adjusting the Temperature sections.
  • C
    Caitlin CampbellAug 20, 2025
    Why is the water temperature too cold in SCUDO Control Unit?
    • D
      Dr. Sandra GardnerAug 20, 2025
      If the water temperature from your SCUDO Control Unit is too cold and the maximum water temperature is incorrectly set, check if the hot water temperature is less than 10ºC above the required blend temperature; if so, adjust the hot water temperature or wait for the water to reheat if a stored system is in use. Also, investigate whether the instantaneous water heater isn't igniting due to a low water flow rate; if this is the case, increase the water flow rate through the system, check and clean or replace the inlet filters, and consult the boiler manufacturer.
  • P
    perryreginaAug 25, 2025
    Why is water leaking from the SCUDO Control Unit showerhead?
    • J
      Jerry MooreAug 25, 2025
      Water leaking from the showerhead of the SCUDO Control Unit for a short time after turning it off is normal; adjust the showerhead angle in the holder to vary the drawing time as needed. However, if the shower cartridge isn't closing fully, possibly due to waterborne debris, remove and check it, referring to the Maintenance section before dismantling the shower valve.
  • S
    Samantha WolfeAug 30, 2025
    How to adjust maximum water temperature on SCUDO NU-022?
    • M
      Mary ButlerAug 30, 2025
      To address a maximum water temperature that is too hot or cold on your SCUDO Control Unit, reset the maximum water temperature. Refer to the ‘Maximum Temperature setting’ in the Maintenance section and ‘Adjusting the Temperature’ section.
  • N
    nicolegutierrezNov 4, 2025
    How to fix low flow rate and varying temperatures in SCUDO NU-022 Control Unit?
    • A
      Angela HallNov 4, 2025
      If the SCUDO Control Unit shower's water flow is low, temperatures fluctuate, or there's no flow, start by inspecting the showerhead, hose, and filters for blockages and clean them as needed. Ensure the stop or service valve in the water supply pipework to the shower valve is fully open. If you have an instantaneous water heater, ensure the water flow rate or pressure is adequate; if it's too low, increase it. If the water head is below the required minimum, raise the cistern or install a negative head shower booster pump. Also, check the inlet filter for partial blockages, cleaning or replacing it and flushing the pipework. If hot or cold water is being used elsewhere, causing pressure or boiler temperature changes, consult the boiler troubleshooting guide. For airlocks or pipework blocka...

Summary

Important Safety Information

General Information

Installation: Shower Valve

Before Installation

Prepare pipework by flushing and isolating water supply before valve installation.

Installation: Wall Arm and Drench Head

Operating the Shower

Instructions on how to operate the shower, including diverter and temperature controls.

Maintenance

General Cleaning

Proper methods for cleaning the shower fitting to maintain its finish.

Cartridge Maintenance

Servicing the shower valve cartridge, especially in hard water areas, for optimal flow.

Adjusting the Temperature

Detailed steps to recalibrate the shower valve's temperature setting.

Troubleshooting