11. Cable sizes
Laying mode = cables on cable tray or racks not perforated / admissible voltage drop = 5% / Multiconductors.
Cable type PVC 70°C (example H07RNF) / Ambient temperature =30°C.
Cable lengths
0 to 50m 51 to 100m 101 to 150m
mm² / AWG mm² / AWG mm² / AWG
Rated Current (A)
Single-phase Three-phase Single-phase Three-phase Single-phase Three-phase
10 4 / 10 1.5 / 14 10 / 7 2.5 / 12 10 / 7 4 / 10
16 6 / 9 2.5 / 12 10 / 7 4 / 10 16 / 5 6 / 9
20 10 / 7 2.5 / 12 16 / 5 4 / 10 25 / 3 6 / 9
25 10 / 7 4 / 10 16 / 5 6 / 9 25 / 3 10 / 7
32 10 / 7 25 / 3 35 / 2
40 16 / 5 35 / 2 50 / 0
50 16 / 5 35 / 2 50 / 0
63 25 / 3
50 / 0
70 / 2 / 0
12. EC Declaration of conformity
Name and address of manufacturer: SDMO, 12 bis rue de la Villeneuve, CS 92848, 29228 BREST CEDEX 2, FRANCE.
Description of the equipment Generating set
Make SDMO
Type
NEO 3000
G. Le Gall, the manufacturer's authorised representative, hereby declares that the product conforms to the following EU Directives:
98/37/EC / Machinery Directive.
2006/95/EC / Low Voltage Directive.
2004/108/EC / Directive on Electromagnetic Compatibility.
2000/14/EC / Directive relating to the Noise Emission of Outdoor
Equipment.
For the directive 2000/14/EC
Notified body:
CETIM
BP 67 F60304 – SENLIS.
Compliance procedure: Appendix VI.
Sound power level guaranteed (Lwa): 95 dB(A).
Rated output: 1.48 kW
06/2009 - G. Le Gall