SDT International LUBExpert Specifications

General IconGeneral
Data LoggingYes
ConnectivityUSB, Bluetooth
Operating Temperature-10°C to 50°C
Storage Temperature-20°C to 60°C
Battery Life10 hours
DisplayColor Display
SensorsTemperature

Summary

Before You Begin

Good to Know

Key operational points and battery recommendations for the LUBExpert device.

Recommended Calibration Intervals

Details SDT's recommendations for annual calibration and warranty program adherence.

Declaration of conformity

States compliance with applicable European Directives and the CE logo.

Warranty

Outlines the conditions required for LUBExpert to be covered by the Limited Lifetime Warranty Program.

Use of IP

Details the terms and conditions for using SDT's intellectual property and content.

Welcome Message

Introduction

What is LUBExpert?

Explains LUBExpert as an ultrasound solution dedicated to bearing lubrication tasks.

Description

LUBExpert is available in three forms

Details the different versions of LUBExpert: Kit, Dynamic Kit, and Upgrade.

LUBExpert Kit

Lists the hardware features and functions of the LUBExpert Ultrasound Data Collector.

LUBExpert Base Kit Hardware

Enumerates specific hardware components and capabilities of the LUBExpert Base Kit.

LUBExpert Data Management Software

Describes the Ultranalysis Suite UAS3 software for managing LUBExpert data.

LUBExpert Base Kit Contents

Itemizes the components included in the LUBExpert Base Kit and accessory packs.

LUBExpert Upgrade for SDT270SU or SDT270DU (MK2 Only)

Information on the upgrade process and criteria for SDT270 devices to gain LUBExpert functionality.

Charging the Battery

Provides step-by-step instructions on how to charge the LUBExpert device battery.

Turning the LUBExpert “ON” and “OFF”

Explains the procedure for powering the LUBExpert device on and off using the power button.

Getting Started

Have you Installed UAS3?

Guides users on installing the necessary UAS3 software and SDT device driver.

Are UAS3 and LUBExpert up to date?

Advises on checking for the latest firmware and software updates for optimal performance.

System Settings Edits

Grease Gun Management

Explains how to configure and manage grease guns within the UAS3 software settings.

Lubricant Management

Details how to manage different types of lubricants used for bearing greasing in UAS3.

Sensor Options – LUBExpert Mode

Guides on selecting specific sensors (LUBEsense1, TEMP2) for LUBExpert mode in UAS3.

LUBExpert databases in UAS3

Managing Databases

Covers creating and managing data folders and tree structures for LUBExpert data in UAS3.

Modifying a Database

Explains how to add descriptive and measurement tree nodes to the database structure.

Add Descriptive Tree Nodes

Details the process of adding descriptive nodes to categorize physical assets.

Add Measurement Tree Nodes

Describes adding measurement nodes, specifying sensor types like LUBEsense1.

Assigning LUBExpert Sensors

Guides on linking LUBEsense1 and TEMP2 sensors to measurement nodes in UAS3.

Setting Data Collection Interval, Acquisition Time, and Temperature Emissivity

Explains configuration of data collection settings for LUBExpert measurements.

Working with Work Orders/Surveys

Create a New Work Order/Survey

Details the steps to create new lubrication work orders and surveys within UAS3.

Transfer Survey to LUBExpert

Explains the process of uploading work orders from UAS3 to the LUBExpert device.

Before going to the field

Provides a checklist report to ensure all necessary tools and lubricants are prepared for field work.

In the Field

Connecting LUBEsense1

Provides instructions on how to properly connect the LUBEsense1 ultrasound sensor.

Starting to work – LUBExpert

Outlines the initial operation steps for using the LUBExpert device in the field.

Collecting dynamic data with LUBExpert app (SDT270DU & LUBExpert Dynamic only)

Explains advanced data collection methods using the LUBExpert app and dynamic features.

Transfer Results to PC

Details the procedure for downloading collected lubrication data from the device to a PC.

Viewing Results in UAS3

Selecting, Viewing Trends, Analytics, and Measurement Details

Describes how to view and analyze lubrication data using UAS3 dashboards and metrics.

Reports

Tree View

Explains how the tree view displays alarm and lube status for assets and points.

Dashboard View (Lubesense1 only)

Details the specific dashboard view for analyzing LUBEsense1 sensor data.

Bottom Pane Views

Describes the detailed views of measurements and events available in the bottom pane.

Consumption Reports

Introduces reports for tracking and analyzing lubricant consumption.