Instructions for:
FILTER/REGULATOR -
SA4FR/38
REGULATOR - SA5/RG/14
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according
to these instructions and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL
REQUIREMENTS, WARNINGS AND CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE
PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL
INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
p WARNING! Ensure that Health & Safety, local authority, and general workshop practice
regulations are adhered to when using this equipment.
p WARNING! Disconnect the equipment from the air supply before changing accessories,
servicing or performing any maintenance.
3 Keep the equipment clean and maintain it in good condition (use an authorised service agent).
3 Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be
dangerous and will invalidate the warranty.
p WARNING! Ensure that the correct air pressure is maintained and not exceeded.
3 Keep air hoses away from heat, oil and sharp edges. Check air hoses for wear before each
use and ensure that all connections are secure.
7 DO NOT direct air from the air hose at yourself, others or animals.
3 Drain the compressor air tank daily. Water in the air line will damage equipment.
3 When work is complete ensure that the air supply is turned off.
Heavy-duty aluminium alloy valve assemblies with large gauges dual marked in psi and bar. Pressure control knob can be locked
in position to prevent accidental alteration. SA4FR/38 features integral filter. Air outlets are fitted with shut-off valves.
2. INTRODUCTION & SPECIFICATIONS
SA4FR/38 SA5/RG/14
Max. inlet/output pressure - psi/bar . . . . . . . . . . 174/12. . . . . . . . . . . . . . . 174/12
Working pressure range - psi/bar. . . . . . . . . 30-120/2-8 . . . . . . . . . . . 30-120/2-8
Max. flow rate - cfm . . . . . . . . . . . . . . . . . . . . . . . . 76 . . . . . . . . . . . . . . . . . . 76
Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/8BSP(M) . . . . . . . . . . . 1/4BSP(F)
Outlet. . . . . . . . . . . . . . . . . . . . . . . . . . 2 x 1/4BSP(M) . . . . . . . . 1 x 1/4BSP(M)
3. CONTENT & INSTALLATION
3.1. Confirm that all items are present and undamaged. If any parts are missing or damaged please contact the supplier.
SA4FR/38 - Combined filter/regulator with gauge.
SA5/RG/14 - Regulator and gauge.
3.2. Fig.1 shows a typical air line installation. The filter is located
upstream of the regulator - unless combined - and the
lubricator downstream.
3.2.1. When installing the filter/regulator or regulator ensure that:
a) Gauge is visible
b) Regulator control is accessible
c) Flow direction arrow (SA5/RG/14) matches system air flow.
SA4FR/38 The inlet on is at the base of the filter body and the
outlets are either side of the gauge.
SA5/RG/14 The inlet and outlet are on the sides of the body
with the gauge between them.
Note: To ensure air-tight joints use PTFE tape.
fig. 1
SA4FR/38
SA5/RG/14
SA4FR/38 & SA5/RG/14 - 1 - 041102
Instructions for:
FILTER/REGULATOR -
SA4FR/38
REGULATOR - SA5/RG/14
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according
to these instructions and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL
REQUIREMENTS, WARNINGS AND CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE
PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL
INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
p WARNING! Ensure that Health & Safety, local authority, and general workshop practice
regulations are adhered to when using this equipment.
p WARNING! Disconnect the equipment from the air supply before changing accessories,
servicing or performing any maintenance.
3 Keep the equipment clean and maintain it in good condition (use an authorised service agent).
3 Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be
dangerous and will invalidate the warranty.
p WARNING! Ensure that the correct air pressure is maintained and not exceeded.
3 Keep air hoses away from heat, oil and sharp edges. Check air hoses for wear before each
use and ensure that all connections are secure.
7 DO NOT direct air from the air hose at yourself, others or animals.
3 Drain the compressor air tank daily. Water in the air line will damage equipment.
3 When work is complete ensure that the air supply is turned off.
Heavy-duty aluminium alloy valve assemblies with gauges dual marked in psi and bar. Pressure control knob can be locked in
position to prevent accidental alteration. SA4FR/38 features integral filter. Air outlets are fitted with shut-off valves.
2. INTRODUCTION & SPECIFICATIONS
SA4FR/38 SA5/RG/14
Max. inlet/output pressure - psi/bar . . . . . . . . . . 174/12. . . . . . . . . . . . . . . 174/12
Working pressure range - psi/bar. . . . . . . . . 30-120/2-8 . . . . . . . . . . . 30-120/2-8
Max. flow rate - cfm . . . . . . . . . . . . . . . . . . . . . . . . 76 . . . . . . . . . . . . . . . . . . 76
Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/8BSP(M) . . . . . . . . . . . 1/4BSP(F)
Outlet. . . . . . . . . . . . . . . . . . . . . . . . . . 2 x 1/4BSP(M) . . . . . . . . 1 x 1/4BSP(M)
3. CONTENT & INSTALLATION
3.1. Confirm that all items are present and undamaged. If any parts are missing or damaged please contact the supplier.
SA4FR/38 - Combined filter/regulator with gauge.
SA5/RG/14 - Regulator and gauge.
3.2. Fig.1 shows a typical air line installation. The filter is located
upstream of the regulator - unless combined - and the
lubricator downstream.
3.2.1. When installing the filter/regulator or regulator ensure that:
a) Gauge is visible
b) Regulator control is accessible
c) Flow direction arrow (SA5/RG/14) matches system air flow.
SA4FR/38 The inlet on is at the base of the filter body and the
outlets are either side of the gauge.
SA5/RG/14 The inlet and outlet are on the sides of the body
with the gauge between them.
Note: To ensure air-tight joints use PTFE tape.
fig. 1
SA4FR/38
SA5/RG/14
SA4FR/38 & SA5/RG/14 - 1 - 041102
Question and Answer IconNeed help?

Do you have a question about the Sealey SA4FR/38 and is the answer not in the manual?

Sealey SA4FR/38 Specifications

General IconGeneral
BrandSealey
ModelSA4FR/38
CategoryController
LanguageEnglish

Summary

Safety Instructions and Warnings

General Safety and Operational Precautions

Adhere to regulations, disconnect for maintenance, ensure correct pressure, avoid misuse, and secure connections.

Maintenance and Handling

Keep equipment clean, use genuine parts, check hoses, drain tank, and turn off supply.

Introduction and Specifications

Product Overview and Features

Heavy-duty aluminium alloy construction, dual gauges, lockable pressure control, integral filter, and shut-off valves.

Technical Data and Model Specifications

Detailed specifications including pressure ratings, flow rate, and connection types for SA4FR/38 and SA5/RG/14.

Content and Installation Guidelines

Installation Requirements

Ensure gauge visibility, accessible controls, correct flow direction, and secure connections with PTFE tape.

Product Operation and Maintenance

Regulator Adjustment and Locking

How to adjust and lock output pressure using the control knob for safe operation.

Filter Cleaning (SA4FR/38)

Instructions for regular cleaning of the filter element by unscrewing the housing.

Additional Fittings and Compliance

Available Accessory Fittings

List of optional fittings like nipples and reducers available from the supplier.

Declaration of Conformity

Statement of conformity with EU directives and manufacturer's construction file availability.

Related product manuals