EasyManua.ls Logo

SECO-LARM ENFORCER SA-025Q User Manual

SECO-LARM ENFORCER SA-025Q
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Multi-Purpose
Programmable Timer
SA-025Q
Installation Manual
The SA-025Q Programmable Timer Module is suitable for a wide range of timed security and
access control operations. Auto-sensing of input voltage and DIP switches for programming make
installation easy.
Timer can be set from 1 second to 60 minutes
Can be triggered via an N.O. positive (+) trigger input signal or an N.C. negative (-) trigger
device or by powering up the unit
Relay can be programmed to activate at the start or at the end of the timing cycle
Relay can also be set to activate for one second at the end of the timing cycle
Relay can be programmed to pulse (flash) or be steady on
Built-in reset function to manually reset timing cycle
Form-C relay, contact rated 10A@24VDC/250VAC
LED indicates relay is energized
12~24VDC operation (auto sensing)
Current draw – Less than 1mA (standby) or 40mA (relay energized)
Functions programmed via DIP switches – no jumpers to cut
Question and Answer IconNeed help?

Do you have a question about the SECO-LARM ENFORCER SA-025Q and is the answer not in the manual?

SECO-LARM ENFORCER SA-025Q Specifications

General IconGeneral
Relay Rating1A@30VDC
Relay ContactsSPDT
Dimensions2.36" x 1.57" x 0.9" (60 x 40 x 23 mm)
Timer TypeDigital
TypeTimer
Voltage12V DC
Operating Voltage12~24 VDC
Current20mA
Operating Temperature-4°~140° F (-20°~60° C)

Summary

Multi-Purpose Programmable Timer SA-025Q

Product Overview and Key Features

Details the suitability of the SA-025Q timer for security and access control, highlighting auto-sensing and DIP switch programming, along with its main features.

Specifications

Key Technical Specifications

Lists essential technical details including operating voltage, current draw, relay contact rating, operating temperature, and dimensions.

Wiring and DIP Switch Settings

DIP Switch Functions

Explains the wiring connections and the functions of each DIP switch for programming timer operations and modes.

Setting the Timer Duration

Provides instructions on how to set the relay output time using the thumbwheel and DIP switch 4 for seconds or minutes.

Sample Applications

Momentary Trigger Configurations

Illustrates common applications like momentary trigger, no delay, and swinger eliminator setups with DIP switch settings and actions.

N.O. vs. N.C. Output Usage

Explains how to use Normally Open (N.O.) and Normally Closed (N.C.) relay outputs for different applications like annunciators or supervisory circuits.

One-Time Momentary Trigger

Details a one-second momentary trigger configuration, including DIP switch settings and reset procedures.

Latched Output Configuration

Describes how to configure the timer for a latched output, including delayed activation and reset methods.

Pulsing or Flashing Output

Explains settings for pulsing or flashing outputs, covering instant/delayed start and specific on/off duration control.

Negative or Closed-Circuit Trigger

Covers the setup for optional negative or closed-circuit triggers, including the required 1kΩ resistor installation.

Important Information

Legal, Warranty, and Notice

Contains critical disclaimers regarding law compliance, Proposition 65 warning, product warranty, and policy on specifications.

Related product manuals