EasyManua.ls Logo

SECO-LARM Enforcer SD-927PKC-NEQ User Manual

SECO-LARM Enforcer SD-927PKC-NEQ
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Wave-to-Open Sensors
Installation Manual
SD-927PKC-NEVQ
SD-927PKC-NEQ
5024193
Conforms to
UL294
Model
Size
Override Button
SD
-
927PKC
-
NEQ
Single
-
gang
12~24 VAC/VDC
No
SD
-
927PKC
-
NEVQ
Single
-
gang
12~24 VAC/VDC
Yes
*Spanish and French faceplates also available.
The ENFORCER Wave-To-Open Sensors use IR technology to request egress from a protected
area or activate a device with the simple wave of a hand. Since no touch is required, they are
suitable for use in hospitals, clinics, labs, cleanrooms (to reduce the risk of contamination),
schools, factories, or offices. The SD-927PKC-NEVQ adds a manual override button as a backup
to the sensor. Also available with Spanish (SD-927PKC-NSQ, SD-927PKC-NSVQ) or French
(SD-927PKC-NFQ, SD-927PKC-NFVQ) faceplates.
Operating voltage, 12~24 VAC/VDC
Range adjustable from 2
3
/
8
"~8" (6~20 cm)
Stainless steel single-gang plate
3A relay, adjustable from 0.5~30 sec, toggle, or as long as hand is near the sensor
LED illuminated sensor area for easy identification
Selectable LED colors (turns from red to green or green to red) when activated
Quick connect screw-less terminal block
Power must be provided by low-voltage power-limited/Class 2 power supply
Use only low-voltage field wiring and do not exceed 98.5ft (30m)
Question and Answer IconNeed help?

Do you have a question about the SECO-LARM Enforcer SD-927PKC-NEQ and is the answer not in the manual?

SECO-LARM Enforcer SD-927PKC-NEQ Specifications

General IconGeneral
BrandSECO-LARM
ModelEnforcer SD-927PKC-NEQ
CategoryAccessories
LanguageEnglish

Summary

Product Overview and Specifications

Product Description

Details the IR technology for egress and its applications in various environments, highlighting the override button feature.

Parts List

Lists the components included with the Wave-to-Open Sensors, such as the sensor unit and mounting screws.

Specifications

Provides detailed technical data for both SD-927PKC-NEQ and SD-927PKC-NEVQ models, including voltage, current, and dimensions.

Installation and Configuration

Installation Notes

Includes crucial safety and compliance information for electrical wiring and grounding according to local and national codes.

Adjusting Sensor Range and Output Timer

Explains how to adjust the sensor's detection range and the relay output duration using potentiometers.

Adjusting LED Color

Details how to change the LED indicator color for standby and triggered states by repositioning a jumper.

Sample Installations and Wiring

Installation with Electromagnetic Lock

Illustrates wiring configurations for connecting the sensor to an electromagnetic lock and a power supply.

Installation with Electromagnetic Lock and Keypad

Shows wiring diagrams for integrating the sensor with a keypad, lock, and power supply system.

Override Button Wiring

Provides specific wiring instructions for the manual override button on the SD-927PKC-NEVQ model.

Care, Troubleshooting, and Warnings

Care and Cleaning

Offers guidance on maintaining the sensor's performance and lifespan through proper cleaning techniques.

Troubleshooting

Addresses common issues like unexpected triggers or sensors remaining triggered, offering solutions.

Important Warnings

Covers crucial safety information regarding mounting, electrical hazards, and California Proposition 65 compliance.