PARAMETER
Voltage(L1-phase)
AverageVoltage
Voltage(L2-phase)
Voltage(L3-phase)
Voltage(L1-L2phase)
SYMBOL
L1
L2
L3
L1L2
L1L2L3
Voltage(L2-L3phase)
L2L3
Voltage(L1-L3phase)
L1L3
Frequency
Hz
PhaseAsymmetry
As%
Presstoentersubmenufrommainmenu
Press+or+tochangeparametervalue
Pressortoscroll
throughsubmenu
Password(PW)
DISPLAY
(For1sec)
DESCRIPTION
RANGE
DEFAULT
VALUE
CONDITION
Presstoentersubmenufrommainmenu
Press+or+tochangeparametervalue
Pressortoscroll
throughsubmenu
Factoryset(RST)
Reset
(Factoryset)
YES/NO
DISPLAY
(For1sec)
DESCRIPTION
RANGE
DEFAULT
VALUE
CONDITION
Presskeyfor3sec.toenterorexit TripValueSettingmenu:
TRIPVALUESETTING
Press+or+tochangeparametervalue
Pressortoscroll
throughmainmenu
YES/NO
Thisoptionwillpromptedfirst
whentheuserentersthetrip
settingmenu.Userhastoset
NOafterwhichhecanaccess
thetripsettingmenu.
LOCK
DISPLAY
(For1sec)
DESCRIPTION
DEFAULT
VALUE
CONDITION
LOCK
YES/NO(InthisoptionifYESisselectedbytheuser,thenwhenever
theuserenterstheTripValueSetting,initiallyLOCKoptionwillbe
prompted.TheuserwillhavetosetNOafterwhichhecanaccessthe
tripsettingmenu.IftheuserwantstodisableLOCKoption,hecanset
NOwhenLOCKoptionispromptedafterTR2option.)
Press+or+tochangeparametervalue
Pressortoscroll
throughmainmenu
DISPLAY
(For1sec)
DESCRIPTION
RANGE
DEFAULT
VALUE
CONDITION
Setover
voltagefor
Relay1
85-500V(Default:498)
[For3P3Wsystem]
50-288V(Default:264)
[For3P4Wsystem]
Setunder
voltagefor
Relay1
85-500V(Default:332)
[For3P3Wsystem]
50-288V(Default:184)
[For3P4Wsystem]
Setover
voltagefor
Relay2
85-500V(Default:498)
[For3P3Wsystem]
50-288V(Default:264)
[For3P4Wsystem]
Setunder
voltagefor
Relay2
85-500V(Default:332)
[For3P3Wsystem]
50-288V(Default:184)
[For3P4Wsystem]
Triptime
delayfor
Relay1
0.0-300s
S
R1
tt
Triptime
delayfor
Relay2
0.0-300s
S
R2
tt
NOTE :PWoptionwillbeaskedwhentheuserentertheconfig.menuifPWoptionisenabledintheconfigmenuand
theuserhastoenterthepasswordwhichhehassetintheS.PW(setpassword)option.
Individualparameterscanbeviewedwitheverypressofkeys.
R1
*
DefaultPage :Thispageisdisplayedafter3sec.
fromotheronlinepage.
For3P4WsystemaverageofL-Nvoltagesisshown.
For3P3WsystemaverageofL-L voltagesisshown.
*
InTripvaluesetting&configurationmenu,ifnokey
pressedfor30sec.thenunitresumesonlinemode.
NOTE: IfValuesarechanged,thesamesettinginconfigmenuwillalsochangedandviceversa,alsoifRL1is
selectedforRL2inconfigmenunoparameterofRelay2willbepromptedintheabovetripvaluesetting.
TripIndicationonpressofkey:Tripvaluewillbedisplayedtillthekeyispressed.
Presskeyfor3sec.toresetmanually
TRIP INDICATION
RESET
MasterPassword: 753
ONLINEKEYS
Hysteresis(HYS)
Presstoentersubmenufrommainmenu
Press+or+tochangeparametervalue
Pressortoscroll
throughsubmenu
DISPLAY
(For1sec)
DESCRIPTION
RANGE
DEFAULT
VALUE
CONDITION
Hysteresis
forvoltage
1.0-40.0V
V
H
Hysteresis
forfrequency
0.1-2.0Hz
H
Hysteresisfor
Asymmetry
2.0-20.0%
S
A
H
Password
ENB/DIS
Enable/Disablepassword
protectionoption
Willbepromptedonlywhen
Passwordoptionisenabled
Setpassword 0-999
RANGE
V
<
R1
V
<
R1
(Specificationssubjecttochangeasdevelopmentisacontinuousprocess.)
SelecControlsPvt.Ltd.,India
FactoryAddress:
91-22-28476443/1882
I
EL-27/1,ElectronicZone,TTCIndustrialArea,
MIDC,Mahape,NaviMumbai-400710,INDIA.
Tel.No.:+
FaxNo. :+91-22-28471733I Tollfree :1800227353
Website:www.selec.com Email:sales@selec.com
V
<
R2
V
<
R2
Doc.name:OP INST 900VPR-UOP441-V01(Page4of4)