User’s
manual
Breathalyser
Carefully
read
the
entire
user's
manual
before
using
the
device
and
understand
the
safety
measures
and
detailed
operating
instructions
for
the
device.
Store
the
user's
manual
in
a
safe
place
for
future
reference.
If
you
sell
the
device
do
not
forget
to
provide
the
user’s
manual
to
the
new
owner
together
with
the
device
and
its
accessories.
Important
safety
measures
IMPORTANT!!!
Using
the
breathalyser
immediately
after
or
within
15
minutes
of
consuming
alcohol
may
damage
the
detection
sensor
and
there
is
a
danger
of
future
measurements
being
inaccurate.
Unprofessional
operation
of
this
device
is
not
covered
by
the
warranty.
e
Do
not
perform
tests
in
strong
winds
or
in
a
closed
room,
which
is
filled
with
cigarette
smoke
or
contains
alcohol
vapours.
e
Ifthe
flat
batteries
symbol
appears
on
the
display,
replace
them
with
new
ones.
*
Do
not
blow
smoke,
food
or
liquids
into
the
mouthpiece.
e
Use
the
device
only
in
an
environment
where
temperatures
are
between
+10
and
+40
°C.
Use
in
an
environment
outside
this
range
may
damage
the
device
and
may
lead
to
incorrect
test
results.
e
The
level
of
alcoho!
in
the
breath
depends
on
many
factors
that
change
over
time.
The
level
can
change
already
several
minutes
after
the
initial
test.
e
The
measurement
results
of
this
device
cannot
be
used
as
evidence
in
legal
proceedings.
e
The
information
obtained
using
this
device
is
only
informative
in
nature.
We
recommend
that
it is
not
used
for
making
decisions
about
the
ability
to
perform
any
activity
requiring
responsibility.
Several
factors
(e.g.
natural
gas
remains,
smoke
and
undesirable
breath)
may
influence
the
level
of
the
measured
values.
*
Do
not
allow
yourself
or
anybody
else
to
drive
a
vehicle
after
consuming
alcohol.
If
you
have
consumed
alcohol
always
organise
for
a
designated
driver
or
use
an
alternative
form
of
transport.
e
Neither
the
vendor
nor
the
manufacturer
are
responsible
for
damages
caused
by
the
use
of
this
device.
NEVER
DRINK
ALCOHOL
IF
YOU
ARE
PLANNING
TO
DRIVE
A
MOTOR
VEHICLE!!!
Attention:
It
is
recommended
to
have
the
accuracy
of
the
device tested
after
a
year
of
use.
With
more
frequent
use
the
lifetime
of
the
device
may
be
used
up
and
the
measurement
results
may
not
be
accurate.
Question and Answer IconNeed help?

Do you have a question about the Sencor SCA BA02 and is the answer not in the manual?

Overview

The SCA BA02 is a portable breathalyser designed to estimate blood alcohol content (BAC) from a breath sample. It features a digital LCD display with a two-color backlight for clear readings. The device is powered by three 1.5V AAA alkaline batteries and has an automatic shut-off function after 2 minutes to conserve power. Its compact dimensions (107 x 45 x 25 mm) and light weight (approx. 48 g without batteries) make it easy to carry. The breathalyser comes with three blowing tubes for use.

Function Description:

The primary function of the SCA BA02 is to measure the alcohol concentration in a person's breath. It operates within a measuring range of 0.2% to 1.5%. The device provides different indications based on the measured alcohol level:

  • "LO" (low value): Displayed for measured values lower than 0.2%.
  • Concentrated alcohol value: Shown on the display for values between >0.2% and a predefined warning level.
  • Warning value: If the measured value equals or exceeds the warning concentrated value, a sound signal will be made, and "NO DRIVING" (driving forbidden) will flash on the screen for about 25 seconds. The measured value and "NO DRIVING" will remain lit.
  • "HI" (high value) & "NO DRIVING": Appears if the measured value is greater than 1.5%. The sound signal can be canceled by pressing the MODE button.

The device has a preheat sensor that activates upon startup, displaying "WAIT" for about 9 seconds, followed by "PH" and "Sta" intermittently, along with a preheat countdown. Once ready, "READY" appears, accompanied by a sound.

Important Technical Specifications:

  • Measuring Range: 0.2 - 1.5%
  • Battery: 3 x 1.5V AAA alkaline batteries
  • Display: Digital LCD display with a two-color backlight
  • Automatic Shut-off: 2 minutes
  • Duration of Test: ≥ 6 seconds
  • Test Preparation Time: 30 seconds
  • Dimensions (h x w x d): 107 x 45 x 25 mm
  • Weight: Approx. 48 g (without batteries)
  • Warning Calibration Value: 0.2 / 0.3 / 0.5 / 0.8% (user-selectable or factory set)
  • Accessories: 3 blowing tubes

Usage Features:

To use the device, batteries must first be installed. After inserting the batteries, an "AUTO CLEANING" process automatically commences, indicated by a flashing auto-cleaning indicator and a countdown on the display. This process can be interrupted by pressing the ON/OFF button. Before taking a test, it is crucial to rinse your mouth with clean water and avoid smoking or consuming alcoholic beverages for at least 5 minutes.

To initiate a test, press the START button briefly. The device will preheat, and once "READY" is displayed, it is ready for use. A straw or blowing tube should be inserted into the inlet opening above the LCD display. The user then presses and holds the "BLOW" button and blows into the tube constantly for approximately 6 seconds until a sound is made and the measured value appears.

The device includes several safety warnings:

  • Do not use the breathalyser immediately after or within 15 minutes of consuming alcohol, as this may damage the detection sensor and lead to inaccurate future measurements.
  • Avoid performing tests in strong winds or in enclosed rooms filled with cigarette smoke or alcohol vapors.
  • Do not blow smoke, food, or liquids into the mouthpiece.
  • Use the device only within a temperature range of +10 to +40 °C to prevent damage and incorrect results.
  • The measurement results are for informative purposes only and should not be used as legal evidence or for making decisions requiring responsibility.
  • Factors like natural gas remains, smoke, and undesirable breath can influence measured values.
  • It is strictly forbidden to drive if the low warning value is exceeded.

Maintenance Features:

  • Battery Replacement: If the flat batteries symbol appears, replace the batteries with new ones. If the low battery condition indicator light flashes, measurements will not be accurate, and batteries should be replaced immediately.
  • Battery Storage: Remove batteries if storing the device for an extended period to prevent leakage and corrosion. Do not expose batteries to excessive heat, charge, heat, open, short, or throw them into fire. Do not leave discharged batteries in the device or combine different types or new and old batteries.
  • Auto-Cleaning: To ensure accurate measurements, especially after not using the device for longer than 2 weeks or before first use, perform an auto-cleaning process. This involves removing and re-inserting batteries and turning on the device. The process takes approximately 5 minutes, with a countdown on the display and a sound in the last minute. The device will automatically turn off after 1 minute, signaling completion.
  • Accuracy Check: It is recommended to have the device's accuracy tested after a year of use. More frequent use may shorten its lifetime and affect accuracy.
  • Troubleshooting "Err" Message: If "Err" flashes for longer than 5 seconds, it may indicate incorrect handling, such as not pressing and holding the BLOW button during the test or not starting the test within 8 seconds of "READY" appearing.
  • Repeat Measurements: If the difference between two subsequent measurements is greater than 0.1%, repeat the measurement.
  • Clearing Residual Alcohol: To ensure accurate measurements, check for residual alcohol in the device. Wait until "LOW" is shown on the display (by pressing START again), hold down BLOW, and allow fresh air to be sucked into the opening. Gently shaking the device can also help remove alcohol remains.
  • Storage: Store the device in a dry place when not in use.
  • Service: If electrolyte leaks from the batteries or if the device is not working correctly or its efficiency is reduced, have it cleaned by an authorized service center.

The manufacturer and vendor are not responsible for damages caused by the use of this device. The device meets the basic requirements of EU directives.