Sensidyne gilian gilibrator 2 User Manual

Sensidyne gilian gilibrator 2
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
16333 Bay Vista Dr. • Clearwater, FL 33760 • (800) 451-9444 • (727) 530-3602 • (727) 539-0550 [FAX] • www.Sensidyne.com
Revision G • Document No. 850190M
\CALIBRATION SYSTEM
OPERATION & SERVICE MANUAL
Gilibrator
2
2
Advanced Test Equipment Rentals
www.atecorp.com 800-404-ATEC (2832)
®
E
s
t
a
b
l
i
s
h
e
d
1
9
8
1
Question and Answer IconNeed help?

Do you have a question about the Sensidyne gilian gilibrator 2 and is the answer not in the manual?

Sensidyne gilian gilibrator 2 Specifications

General IconGeneral
ModelGilibrator 2
Battery LifeUp to 8 hours
CalibrationNIST Traceable
Resolution0.01 L/min
TypeAir Flow Calibrator
Operating Temperature0 to 45°C (32 to 113°F)
Power SupplyRechargeable battery or AC adapter
DisplayLCD
OutputAnalog output

Summary

PACKING LIST

PROPRIETARY NOTICE

COPYRIGHT NOTICE

TRADEMARK NOTICE

DISCLAIMER

WARNINGS !

IMPORTANT COMPATIBILITY NOTE

Advises on compatibility of existing flow cells with the Gilibrator 2 base unit.

SECTION ONE: INTRODUCTION

1.1 OVERVIEW

Provides a general overview of the Gilian Gilibrator 2 Calibration System's features.

1.2 THEORY OF OPERATION

Explains the airflow measurement principle using volume and time intervals.

SECTION TWO: COMPONENTS

2.1 CONTROL UNIT

Describes the microprocessor control unit, including buttons, display, and interface components.

2.2 Piston Cell Assembly

Details the piston cell assembly, its ready light, bleeder valve, and sensor rail.

2.3 Wet Cell Assembly

Describes the wet cell assembly, bubble generation, and available sizes.

SECTION THREE: SET-UP

3.1 SYSTEM SET-UP

Outlines the initial steps for setting up the Gilibrator 2 Calibration System.

3.2 CELL ASSEMBLY SET-UP

Covers the procedures for mounting and connecting the cell assembly to the control unit.

SECTION FOUR: OPERATION

4.1 PISTON CELL OPERATION

Explains the startup, flow readout, and operational steps for the piston cell.

4.2 WET CELL OPERATION

Details the startup, bubble generation, and flow readout for the wet cell.

SECTION FIVE: STORAGE & MAINTENANCE

5.1 STORAGE

Provides instructions for short-term and long-term storage of the Gilibrator 2 unit.

5.2 PISTON CELL MAINTENANCE

Outlines maintenance procedures and calibration recommendations for the piston cell.

5.3 WET CELL MAINTENANCE

Covers general maintenance, damper plate, and leak checks for the wet cell assembly.

APPENDIX A: PARTS LIST

Calibration Kits

Lists various calibration kits available, categorized by type and specifications.

Accessories

Lists optional accessories that can be used with the Gilibrator 2 system.

Spares

Lists individual replacement parts for the Gilibrator 2 system.

APPENDIX B: SPECIFICATIONS

General Specifications

Provides general technical details on the Gilibrator 2 base unit's construction and controls.

Performance Specifications

Details operating temperature, humidity, and accuracy metrics for the system.

Electrical Specifications

Lists electrical requirements, battery information, and interface connector details.

APPENDIX C: RETURNED MATERIAL AUTHORIZATION

SERVICE OPTIONS

Outlines available service options, including training, technical assistance, and repairs.