At the end of their useful life
the packaging and product
should be disposed of via a
suitable recycling centre.
Do not dispose of with normal
household waste.
Do not burn.
Technical Data
MAXIMUM RECOMMENDED MOUNTING HEIGHT: 3.0m
RANGE: Cone-shaped detection pattern, diameter (at floor level) = 2.4 x mounting height
OFF DELAY: 20 minutes
PHOTOCELL: Adjustable 50-5000 lux
COLOUR: White
MATERIAL: Flame retardant ABS
WEIGHT: 70g excluding cable
IP RATING: 4X
OPERATING VOLTAGE: 230V 50Hz (UK & Europe)
PRODUCT RATING & RECOMMENDED CIRCUIT PROTECTION: 10 Amps
MAXIMUM RECOMMENDED LOAD: 6 Amps
115mm
65mm
50842PL Ed. 1
Installation and Commissioning
Instructions
Note: K4053 or K4050 required for commissioning
User override available via K4052 or K4051
Hand-held Controllers
Standard PIR with Photocell
Slim Flush
Green/Yellow - Earth
(no internal connection)
Blue - Neutral
Black - Live Out
Brown - Live In
K4010
Electrical Connections
6.0m
2.4m
SENSORS
K4010
MK Electric
The Arnold Centre, Paycocke Road, Basildon,
Essex, SS14 3EA. UK
Tel: +44 (0)1268 563720
Fax: +44 (0)1268 563064
email: mktechnical@honeywell.com
Tel: +44 (0)1268 563000
Fax: 01268 563404
Fax: +44 (0)1268 563365 (International)
email: mkorderenquiries@honeywell.com
web site: www.mkelectric.co.uk
Novar ED&S Ltd (A Honeywell Company),
Arlington Business Park, Bracknell, Berkshire, RG12 1EB
All marks in this document identified with a R or TM symbol
adjacent to the mark are Trade Marks of Novar ED&S Ltd.
Technical Help
Customer Service
______________________________________________________
Question and Answer IconNeed help?

Do you have a question about the Sensors K4010 and is the answer not in the manual?

Summary

Electrical Connections

Technical Data

Commissioning

Walk-test Mode

Used to check the range of the presence detector and its switching behavior at the edge of the detection zone.

Setting the Photocell

Adjusts the light level threshold for the photocell to become active, ensuring lights turn on only when needed.

Important Additional Notes