503-692-4052
From U.S. and Canada: 800-547-2556
SENTROL , inc
5150-W
Sentrol On-the-Glass Shock Sensors
5150–W 5150–M
5150C–W 5150C–M
Easy Installation and Range Verification
Mount directly on the glass
Two wire, self powered, solid state
Easy mounting with specially
formulated 3M
adhesive tape
Applications
The 5150 is rated for all types of glass, without
adjustment. The sensor is rated for plate, wired,
tempered and laminated glass up to 1/4".
Shock sensors are intrusion detection devices
designed to detect a glass break big enough to
reach, crawl, or walk through. Shock sensors aren’t
rated to detect cracks, bullet holes and other small
holes, removing windows, or entry via glass cutting
without breakage. All Glassbreak sensors should be
10'
Maximum Coverage
Walk away with confidence
Strike far opposite
corner of glass with
screwdriver handle
Sensor trips at panel or
keypad verifying range
for entire glass area
Glassbreak
Sensors
5150 Series
Shock Sensors
backed up by interior protection.
Laminated Glass will reduce the specified range.
Test carefully to ensure maximum detection. Armor
coated glass and plexiglass will reduce specified
range by 50%, from a 10' radius to a 5' radius.
This shock sensor is self powered and therefore will
not effect battery life for wireless transmitters.
0
46188 06851
7
Mount sensor 1" from the
frame
Quantity 5
X
Protected under patent 4,745,398 re. 33,807 and other patents
Question and Answer IconNeed help?

Do you have a question about the Sentrol 5150-W - Security Glassbreak Shock Sensor and is the answer not in the manual?

Sentrol 5150-W - Security Glassbreak Shock Sensor Specifications

General IconGeneral
BrandSentrol
Model5150-W - Security Glassbreak Shock Sensor
CategorySecurity Sensors
LanguageEnglish

Summary

Sentrol On-the-Glass Shock Sensors

Easy Installation and Range Verification

Details on mounting directly on glass, two-wire power, and adhesive tape installation.

Applications

Information on the sensor's rating for various glass types and coverage.

Installation and Operation

Mounting

Instructions for optimal sensor placement, surface preparation, and adhesion.

Wiring

Guidance on connecting the two-wire, self-powered sensor and wiring recommendations.

Testing

Procedures for testing sensor operation and detection range using a screwdriver rap.