GROUND CONNECTION BETWEEN MOTOR AND HOUSE-PLANT
DAL 1965
Pag. 8/10
MOTOR CONNECTIONS
CR/14
4 5 6 7
R S T
15 16 17
BLUE
BROWN
BLACK
MOT
O
RE
MO
TORE
4 5 6123
CR/14 TECHNICAL DATA
Dimensions................................. 235x155x90 mm
Temperature.............................. -20° ÷ +60°C
Weight.......................................... 1,3 kg
Power supply............................ 230/400V~±10% 50/60 Hz
:
max.power supply / voltage..........1100W / 400 V~
Remote control switches for three-phase motors
WORKING SET-UP
5 ÷ 100 s
Gate open
pause
T1
2 s
11
reverse direction automatic restart
after stopping from photocell drive
on closing action
ON
OFF
2 s
automatic restart in the same
direction after stopping from
photocell drive
22
ON
T1
5 ÷ 100 s
OFF
DIP SWITCH SET-UP
TRIMMER
MOTOR ON THE RIGHT (FACTORY SETUP)
MOTOR ON THE LEFT
To connect the motor on the left-hand side of the
gate, swap the following connections:
4 with 5
16 with 17
MOTOR YELLOW-GREEN CABLE
MOTOR CABLE
CONNECTING CLAMP
CABLE THREE-PHASE 400 V~
POWER SUPPLY
YELLOW-GREEN CABLE
automatic reclosure
manual drive reclosure