EasyManua.ls Logo

SereneLife SLPUMP25 - Inflation Operation; Step-by-Step Inflation; Automatic Stop Feature; Fault Handling

SereneLife SLPUMP25
5 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.SereneLifeHome.com
6
www.SereneLifeHome.com
7
Figure 2
The battery should be recharged immediately after it is discharged. Please do
not lay the pump aside without power for a long time.
The battery must be removed from the appliance before it is scrapped:
the appliance must be disconnected from the supply mains when removing
the battery;
the battery is to be disposed of safely.
VII. INFLATION OPERATION
Use the pump directly in which the battery has been fully charged.
Connect the Flexible adaptor (10) of the hose with the air pump ination inlet
(1), and twist clockwise to tighten it, as Figure 2.
Install the other end (8) of the hose into the nozzle matching the air bag and
turn clockwise to tighten it; then insert the ination valve of air bag, and turn
clockwise to xed rmly, as shown in Figure 3.
Turn on the power switch.
(the symbol
- on the switch means “ON”, o means “OFF”)
Press the pressure unit toggle button to select the unit you need.
Press the pressurizing button or decompressing button to set the
pressure value you need, with the range of the pressure value from 0 to 16PSI,
(1PSI=0.0689BAR)
After nishing the above steps, press the power switch button to start to
inate. During the inating process, you can press the pressurizing button
or decompressing button to increase or reduce the pressure value, press
the pressure unit toggle button to switch the unit, and press the On/O
button to stop.
When the pressure reaches the set value, the air pump will stop working
automatically.
When not in use, turn o the power switch “ ”, remove the hose from the air
pump and air bag and store the product properly. (the symbol
- on the switch
means ON”,
o means “OFF”)
Notice: The factory set pressure value of the air pump is 10PSI (10PSI=0.689BAR),
and at the time of the secondary use, the set pressure value for the last time use
will be displayed by default.
Notice: After powered on, if there is no operation within 2 minutes, the air pump
will enter standby mode, and the machine can be initiated by pressing the power
switch button .
VIII. FAULT HANDLING
Figure 3
Fault Inspection Solution
The air pump
pump won't start
normally.
1. Check if the switch
“ ” is turned on
and the battery is
fully charged.
2. Overheating or
overload causes
motor stop.
1. Turn on the power switch and
charge it in time
2. Cool o the motor and
restart it.
3. If the problem cannot be
solved, please contact local
agents or the similar
authorized personnel.
Slow or abnormal
ination.
1. Check whether
the hose is blocked
or cracked.
2. The joint between
the hose and air
pump or air bag is
not installed
properly.
1. Change the hose or make it
unblocked, and check
whether the hose is cracked.
2. Reinstall the hose.
3. If the problem cannot be
solved, please contact with
the manufacturer or its
service agent or the similar
authorized personnel.

Related product manuals