5kW All-in-one the Hybrid Inverter User Manual
Important Notice
In order to protect the legitimate rights and interests of users, please read our operating procedures and
safety instructions carefully before using this equipment. Please operate the equipment according to the
operating procedures and safety instructions.
Once using this device, you are deemed to have read, understood, endorsed and accepted all terms and
contents of the device's operating procedure
s and safety instructions. The User is committed to being
responsible for his or her actions and all consequences arising therefrom.
The User undertakes to use the device solely for legitimate purposes and agrees to these Terms and any
relevant national policies or guidelines.
In using this equipment, please strictly observe and implement the requirements including but not limited to
the operating procedures and safety instructions. All personal injury, accident, pr
operty damage, legal
disputes and other adverse events that cause conflicts of interest caused by violations of the user instructions
or force majeure indicated by the safety instructions are the responsibility and loss of the User. Our company
will not assume any responsibility.
Copyright, all rights reserved. The content is subject to change without notice.
Caution!
Failure to observe a warning indicated in this manual may result in injury.
The danger of high voltage
and electric shock!
Refer to the operating instructions
Signals danger due to electrical shock and indicates the time(5 minutes)to
allow after the inverter has been turned off and disconnected to ensure safety
in any installation operation.
The danger of hot surface!
Protective earth

Questions and Answers

  • L
    Luke PetersAug 19, 2025
    What to do if Sermatec SMT-5K-TL-LV Inverter displays Output Current Leakage Error?
    • N
      Nicholas HamiltonAug 19, 2025
      If you encounter an Output Current Leakage Error on your Sermatec Inverter, there are a couple of things to check: * First, shut down the inverter and inspect the AC output circuit, ensuring the PE is properly grounded. Restart the inverter after making corrections. * Second, make sure that the leakage current of the load meets the standard (less than 230mA), as an excessive leakage current from the load could be the cause.
  • W
    Wesley MurphyAug 21, 2025
    Why does my Sermatec SMT-5K-TL-LV Inverter show Grid Frequency High Warning?
    • K
      Kevin MorrisonAug 21, 2025
      If your Sermatec Inverter is showing a Grid Frequency High Warning, it indicates that the grid frequency is higher than the upper limit. You should check the grid frequency and restart the inverter after the grid frequency recovers to the normal range.
  • N
    Nicole WilliamsAug 23, 2025
    Why does my Sermatec SMT-5K-TL-LV Inverter show Grid Frequency Low Warning?
    • B
      bennettfernandoAug 23, 2025
      If your Sermatec Inverter is showing a Grid Frequency Low Warning, it means that the grid frequency is lower than the lower limit. You should check the grid frequency and restart the inverter after the grid frequency recovers to the normal range.
  • A
    andersonamandaAug 26, 2025
    Why does my Sermatec Inverter show Grid Voltage High Warning?
    • P
      pdennisAug 26, 2025
      If you're seeing a Grid Voltage High Warning on your Sermatec Inverter, it means the grid voltage is higher than the upper limit. Check the grid voltage and restart the inverter after the grid voltage recovers to the normal range.
  • M
    Mackenzie HowardAug 27, 2025
    Why does my Sermatec SMT-5K-TL-LV show Grid Voltage Low Warning?
    • B
      Barbara NelsonAug 27, 2025
      If your Sermatec Inverter displays a Grid Voltage Low Warning, it indicates that the grid voltage is lower than the lower limit. Check the grid voltage and restart the inverter after the grid voltage recovers to the normal range.
  • V
    Veronica CollinsAug 30, 2025
    How to fix Grid Phase Lock Failure on Sermatec SMT-5K-TL-LV Inverter?
    • S
      Shirley LyonsAug 30, 2025
      A Grid Phase Lock Failure on your Sermatec Inverter indicates an abnormal frequency or voltage of the grid. Shut down the inverter and turn it back on when the power grid is normal.
  • J
    Jennifer CollierSep 1, 2025
    What to do if Sermatec Inverter shows AC Output Short Circuit Error?
    • A
      April BrownSep 1, 2025
      If your Sermatec Inverter displays an AC Output Short Circuit Error, it indicates a short circuit issue with the AC backup or AC Grid port. To resolve this, shut down the inverter, check the circuit for any short circuits, and restart it after correcting the issue.
  • J
    John SmithSep 3, 2025
    Why does my Sermatec Inverter show PV2 Overvoltage Warning?
    • M
      Mrs. Ashley PetersonSep 3, 2025
      If your Sermatec Inverter displays a PV2 Overvoltage Warning, it indicates that the voltage of PV2 is higher than the upper limit. Check the PV2 configuration and reduce the PV open-circuit voltage.
  • J
    Jessica GriffinSep 5, 2025
    What to do if Sermatec SMT-5K-TL-LV shows Battery Overvoltage Warning?
    • G
      gsandersSep 5, 2025
      If your Sermatec Inverter shows a Battery Overvoltage Warning, it means the battery voltage is higher than the upper limit. Check the battery voltage, and reduce the battery voltage or change the battery if necessary.
  • B
    Brooke ReedSep 7, 2025
    What to do if Sermatec Inverter shows Battery Undervoltage Warning (EOD)?
    • V
      Vincent ShortSep 7, 2025
      If your Sermatec Inverter displays a Battery Undervoltage Warning (EOD), it means the battery voltage is lower than the lower limit. Check the battery voltage and increase it, or replace the battery if needed.

Summary

Summary

Model Description and Operating Principles

Details the inverter model's naming convention, composition, and operating principles.

Work Modes

General Mode

Suitable for stable grids; explains PV, battery, and grid interactions.

Energy Storage Mode

For unstable grids, focusing on battery charging and discharge.

Micro-grid Mode

For areas without a grid, relying on PV and battery power.

Peak-Bottom Mode

Operates based on electricity price periods (tip, peak, flat, bottom).

AC Coupling Mode

Integrates with existing grid-tied inverters for storage system profit.

Installation

Safety Regulations

Essential safety rules for installing the high-voltage hybrid inverter.

Preparation and Requirements

Covers unpacking, cable/switch prep, kit, and installation site requirements.

Mounting and Electrical Connections

Guides for physically mounting the inverter and making all electrical connections.

Specific Cable Connections

Detailed steps for connecting PV, Battery, AC output, and communication cables.

Installation Check

Checklist for verifying proper installation and electrical connections.

System Commissioning

Pre-Commissioning Checks

Checklist of safety and operational checks before powering on the system.

Power On and Off Procedure

Step-by-step procedures for powering the inverter on and off.

Product Maintenance

Routine Maintenance and LED Status

Periodic checks for system upkeep, status, and understanding LED indicators.

Troubleshooting Common Issues

Lists common error messages, fault causes, and solutions for troubleshooting.

Technical Parameters

PV Input and Battery Parameters

Technical specifications for DC PV input and battery charging/discharging.

Grid and Load Output Parameters

Technical specifications for grid connection, load output, efficiency, and standards.

Environment, Dimensions, and Weight

Specifies operating environment limits, IP rating, dimensions, and weight.

Sermatec SMT-5K-TL-LV Specifications

General IconGeneral
BrandSermatec
ModelSMT-5K-TL-LV
CategoryInverter
LanguageEnglish