Servona Servoport 3000 m - User Manual

Servona Servoport 3000 m
26 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
DEUTSCH
DEUTSCH
24336/0903
Gebrauchsanweisung
Absauggerät
Servoport 3000 m
Gebrauchsanweisung
Instruction Manual
0197
Distributor | Distributeur:
Servona GmbH
Biberweg 2
4-26 | 53842 Troisdorf | GERMANY
P.O. Box 92 01 06 | 53831 Troisdorf | GERMANY
Tel. +49 (0)22 41.93 22-0
Fax +49 (0)22 41.93 22-277
info@servona.de | www.servona.de
zur Verfügung gestellt von Gebrauchs.info
Aktualisierungsstand Gebrauchs.info November 2011

Table of Contents

Questions and Answers

  • G
    Gloria ThomasAug 10, 2025
    What to do if vacuum values are 0.04 MPa but suction force declines in Servona Medical Equipment?
    • P
      Paul BellAug 10, 2025
      If the vacuum value reads 0.04 MPa on your Servona Medical Equipment, but suction at the hose opening is weak or nonexistent, the overflow protection device may have been triggered. Try turning the vacuum controller counter-clockwise to discharge the vacuum, then empty the secretion container and turn the controller clockwise again. Also, the suction hose or bacterial filter might be blocked. Clean or replace the hose, and replace the bacterial filter with a new one.
  • F
    Fred ClementsAug 15, 2025
    How to fix vacuum not attaining maximum value in Servona Servoport 3000 m?
    • M
      Michael KimAug 15, 2025
      If the vacuum on your Servona Medical Equipment isn't reaching its maximum value, there could be a few reasons. Check for leakage at the secretion container inlet; clean the inlet and ensure the lid is tightly secured. The vacuum controller might be inaccurate, so try turning it down. Also, inspect the hose connections for leaks and connect the hoses correctly.
  • L
    larsenmelissaAug 22, 2025
    What to do if Servona Servoport 3000 m doesn't work but power supply is OK?
    • M
      mmartinAug 22, 2025
      If your Servona Medical Equipment isn't working even with a good power supply, and the charging LED is off, the plug or socket contact might be defective; repair or replace the socket. Alternatively, the fuse may have blown, so replace it.
  • K
    Katie DunlapAug 28, 2025
    Why is fluid spurting out of the suction outlet in my Servona Servoport 3000 m?
    • A
      alan44Aug 28, 2025
      If fluid spurts out of the suction outlet of your Servona Medical Equipment, it's likely due to an overflow protection fault. The suggested solution is to repair or replace the defective overflow protection device.
  • N
    Natalie KochSep 2, 2025
    What to do if fuse blows immediately in Servona Servoport 3000 m?
    • C
      Christina CummingsSep 2, 2025
      If the fuse blows immediately when your Servona Medical Equipment is connected to the mains voltage, it indicates an electrical fault or overvoltage. Check the circuit to eliminate the problem.

Summary

2.0 Safety instructions

3.0 Installation and initial operation

3.1 Operational controls

Identifies and explains the various controls and indicators on the Servoport 3000m unit.

3.2 Connection

Instructions for checking the apparatus, mains adapter, and connections before setup.

4.0 Operation

4.1 Setting vacuum

How to adjust and set the desired vacuum level using the regulator and meter.

4.2 Suction catheter

Instructions for connecting the suction catheter to the hose and using the auxiliary air opening.

4.3 Suction

Guidance on performing the suction process and the function of the overflow protection device.

5.0 Cleaning, disinfection

5.1 Recommended instrument disinfectants

Lists recommended disinfectants for instrument parts and their contents.

5.2 Recommended surface disinfectants

Lists recommended disinfectants for cleaning the apparatus surface and their contents.

6.0 Inspection, reconditioning, and disposal

6.1 Inspection

Requirements for regular safety inspections and maintenance of the suction apparatus.

7.0 Troubleshooting

9.0 Technical data

11.0 Information on EMC

11.1 Guidelines and manufacturers declaration - Electromagnetic emissions

Details electromagnetic emission levels and guidelines for the Servoport 3000m.

Servona Servoport 3000 m Specifications

General IconGeneral
BrandServona
ModelServoport 3000 m
CategoryMedical Equipment
LanguageEnglish