13
Check battery voltage
and adjust Low Voltage
Cut-Of f as required.
Fan fault (electric current ) / >0.65A
Frequent start-stop.
Contact seller.
The compressor starts incorrectly
(The motor is blocked or the
pressure dif ference of the cooling
system is too large).
Ambient temperature
may be too high,
please clear the air
vents, if the problem
hasn't been solved,
please contact seller.
The compressor speed is too low
(the refrigeration system is
overloaded and the motor cannot
be maintained 1850r/min as
minimum speed) the requirements.
Protects the compressor control
module from over-temperature or
under-temperature (When the
ambient temperature is too high or
too low, or the system is
overloaded making the module/
ECU internal temperature100°C
or -10°C).
NTC short circuit fault.
Battery voltage low protection
(Module input voltage is lower than
the set value).
CADE Error Type Action
6.3 ERROR CODES & SOLUTIONS
When the refrigerator fails, the digital screen displays the
failure mode, as shown in the following table:
NTC open-circuit fault.
Contact seller.
E1
E2
E3
E4
E5
HH
LL