EasyManua.ls Logo

Sharp 4T-B70CJ1U - Page 20

Sharp 4T-B70CJ1U
63 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4T-B70CJ1 TROUBLE SHOOTING 4 - 18
4. LIST OF ADJUSTMENT PROCESS MODE MENU
(*) The page number will be changed at the running change. For the number to be changed, please check ( ).
PAGE(*)
NUMBER
PAGE
TITLE
ITEM
FUNCTION
1/7
INFO
Main version
Main Software Version.
(Detail) Eel_ATSC_Pack**_v*.**(****)
V*.** : SW version
(****) : Boot version
SVN Number
Don’t care
PANEL Version
Don’t care
TEMP SENSOR
TEMP sensor (Thermistor) value every 200msec.
NORMALSTANDBT CAUSE
Cause of last Stand-By Operation.
(Detail) NONE / Remote control / Keyboard / RS232C / No signal off /
No operation off / Sleep timer
ERROR STANDBY CAUSE
Cause of last (up to 5) Error Protection Stand-By Operation and TIME.
(If the times have more than 5, the latest information should display at the
bottom.)
2/7
INIT
Factory Init
Initialization for factory settings
Panel Setting
LCD panel module information
Public Mode
Change of Enable/Disable access to Public Setting MENU.
Operation Acutime
Accumulate Time of TV-SET Operation.
RESET
Reset the Accumulate Time of TV-SET Operation.
3/7
WB ADJ
IN POINT LOW
Standard value Low (In AV MODE : STANDARD,MOVIE,GAME,USER,PC)
IN POINT HIGH
Standard value High
R LEVEL LOW
WB adjustment Point Low ,R adjustment value
G LEVEL LOW
WB adjustment Point Low ,G adjustment value
B LEVEL LOW
WB adjustment Point Low ,B adjustment value
R LEVEL HIGH
WB adjustment Point High ,R adjustment value
G LEVEL HIGH
WB adjustment Point High ,G adjustment value
B LEVEL HIGH
WB adjustment Point High ,B adjustment value
R LEVEL MAX
WB adjustment Point Max ,R adjustment value
G LEVEL MAX
WB adjustment Point Max ,G adjustment value
B LEVEL MAX
WB adjustment Point Max ,B adjustment value
ADJ DATA STORE
Update and Store all of gamma register value
RESET ADJUSTMENT
Reset default value above items and Adj-Flag
4/7
ETC
EEP CLEAR
Clear the EEPROM data to 0xFF.
STANDBYCAUSE RESET
Clear the STANDBY CAUSE history.
DESTINATION
Indicate the kind of Factory-Initialization command
L ERR RESET
Indicate the count of Lamp Error Protection. And Reset the counter
L ERR STOP
Lamp Error protection flag (Enable/Disable)
TEMP CAUTION
Setting for threshold level of High-Temp. caution (THRS1)
TEMP SHUTDOWN
Setting for threshold level of High-Temp. protection (THRS2)
5/7
PANEL
VCOM ADJ
V-COM adjustment value
TCON TEST PATTERN
Display the T-CON Test Pattern
TEST PATTERN
Display the Test Pattern.

Related product manuals