4T-B70CJ1 TROUBLE SHOOTING 4 - 18
4. LIST OF ADJUSTMENT PROCESS MODE MENU
(*) The page number will be changed at the running change. For the number to be changed, please check ( ).
PAGE(*)
NUMBER
PAGE
TITLE
ITEM
FUNCTION
1/7
INFO
Main version
Main Software Version.
(Detail) Eel_ATSC_Pack**_v*.**(****)
V*.** : SW version
(****) : Boot version
SVN Number
Don’t care
PANEL Version
Don’t care
TEMP SENSOR
TEMP sensor (Thermistor) value every 200msec.
NORMALSTANDBT CAUSE
Cause of last Stand-By Operation.
(Detail) NONE / Remote control / Keyboard / RS232C / No signal off /
No operation off / Sleep timer
ERROR STANDBY CAUSE
Cause of last (up to 5) Error Protection Stand-By Operation and TIME.
(If the times have more than 5, the latest information should display at the
bottom.)
2/7
INIT
Factory Init
Initialization for factory settings
Panel Setting
LCD panel module information
Public Mode
Change of Enable/Disable access to Public Setting MENU.
Operation Acutime
Accumulate Time of TV-SET Operation.
RESET
Reset the Accumulate Time of TV-SET Operation.
3/7
WB ADJ
IN POINT LOW
Standard value Low (In AV MODE : STANDARD,MOVIE,GAME,USER,PC)
IN POINT HIGH
Standard value High
R LEVEL LOW
WB adjustment Point Low ,R adjustment value
G LEVEL LOW
WB adjustment Point Low ,G adjustment value
B LEVEL LOW
WB adjustment Point Low ,B adjustment value
R LEVEL HIGH
WB adjustment Point High ,R adjustment value
G LEVEL HIGH
WB adjustment Point High ,G adjustment value
B LEVEL HIGH
WB adjustment Point High ,B adjustment value
R LEVEL MAX
WB adjustment Point Max ,R adjustment value
G LEVEL MAX
WB adjustment Point Max ,G adjustment value
B LEVEL MAX
WB adjustment Point Max ,B adjustment value
ADJ DATA STORE
Update and Store all of gamma register value
RESET ADJUSTMENT
Reset default value above items and Adj-Flag
4/7
ETC
EEP CLEAR
Clear the EEPROM data to 0xFF.
STANDBYCAUSE RESET
Clear the STANDBY CAUSE history.
DESTINATION
Indicate the kind of Factory-Initialization command
L ERR RESET
Indicate the count of Lamp Error Protection. And Reset the counter
L ERR STOP
Lamp Error protection flag (Enable/Disable)
TEMP CAUTION
Setting for threshold level of High-Temp. caution (THRS1)
TEMP SHUTDOWN
Setting for threshold level of High-Temp. protection (THRS2)
5/7
PANEL
VCOM ADJ
V-COM adjustment value
TCON TEST PATTERN
Display the T-CON Test Pattern
TEST PATTERN
Display the Test Pattern.