Cycle temperature and service port pressure
ISO Cooling and Heatpump condition
(at 220V REFRIGERANT PIPE LENGTH 7.5 m)
Dimension of Capillary tube
ISO Cooling and Heatpump condition
O.D. I.D. L
Capillary tube A
Capillary tube B
MODEL
ø 2.7 ø 1.5
ø 1.4
800
600ø 2.7
O.D. I.D.
AE-A079E AE-A099E
L
ø 2.7 ø 1.5
ø 1.5
700
700ø 2.7
AY-A079E
78˚C 65˚C
43˚C 2˚C
11˚C 33˚C
8˚C 1 ˚C
0.52MPa 1.49MPa
AY-A099E
80˚C 84˚C
Cooling Heating Cooling Heating
44˚C 1˚C
11˚C 35˚C
6˚C 3 ˚C
0.47MPa 1.75MPa
Service port pressure
Model
NO. Condition
1
2
3
4
Gauge pressure
Indoor side
Outdoor side
Temperature (˚C) Temperature (˚C)Relative humididity (%) Relative humididity (%)
27 47 35 40