EasyManuals Logo

Sharp AE-X138E User Manual

Sharp AE-X138E
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
AH/AU-X108E
AY/AE-X108E
AH/AU-X138E
AY/AE-X138E
13
OUTDOOR UNIT for AE-X108E / AE-X138E / AU-X108E / AU-X138E
CPU
Test mode circuit
LED drive circuit
Winter kit circuit (option)
Heat exchanger pipe 
thermo circuit
Compressor thermo circuit
CPU reset circuit
Serial I/O circuit
Power transistor module 
drive circuit
4-way valve drive circuit
(except for AU-X138E,AU-X108E) (except for AU-X138E,AU-X108E)
Outdoor fan relay drive
circuit
Power supply
circuit (built
into IPM)
CPU oscillator circuit
AC overcurrent detection
circuit
DC overcurrent detection
circuit
LED
Heat exchanger pipe
thermistor
Compressor thermistor
Current transformer
Outdoor temperature
thermo circuit[except for the
AU-X138E and AU-X108E]
Outdoor temperature
thermistor[except for the 
AU-X138E and AU-X108E]
Compressor
Power 
transistor module
4-way valve
Outdoor fan
Smoothing
circuit
Passive filter
circuit
Filter
circuit
Unit-unit
wiring (AC
power and
serial
signals)
protection
20A : AU-X138E, AE-X138E
13A : AU-X108E, AE-X108E
AU-X108E, AE-X108E
20A : AU-X138E, AE-X138E
10A :
protection
3 A
protection
Heat exchanger pipe
thermistor(option)
Outdoor temperature
thermistor(option)
[except for the AU-X138E 
and AU-X108E]