35
Temperature at each part and pressure in 3-way valve
Operation 
mode
Cool
(Max.)
Cool
1
2
3
4
3-way valve
pressure
(kg/cm
2
G)
97˚C
43˚C
14˚C
16˚C
5.2
72˚C
43˚C
15˚C
11˚C
6.1
75 50 settle
AH-X108E
No.
Hz
Operation 
mode
Cool
(Max.)
Cool
1
2
3
4
3-way valve
pressure
(kg/cm
2
G)
97˚C
43˚C
14˚C
13˚C
4.9
73˚C
42˚C
16˚C
17˚C
6.6
94 50 settle
AH-X138E
No.
Hz
Capillary tube
O.D I.D. L
ø2.7 ø1.5 800
AH-X108E
Capillary tube
O.D I.D. L
ø2.7 ø1.6 500
AH-X138E
Dimension of Capillary tube
Indoor side
Standard conditions: 
Dry-bulb Temp. (˚C) Relative Humidity (%)
27
20
Cooling
Heating
47
Outdoor side
Dry-bulb Temp. (˚C) Relative Humidity (%)
35
7
40
87
AY-X108E, AY-X138E
Temperature at each part and pressure in 3-way valve
Operation 
mode
Cool
(Max.)
Heat
(Max.)
Cool Heat
1
2
3
4
3-way valve
pressure
(kg/cm
2
G)
98˚C
43˚C
14˚C
16˚C
5.0
96˚C
0˚C
35˚C
2˚C
18.4
72˚C
43˚C
15˚C
11˚C
6.0
59˚C
2˚C
32˚C
2˚C
13.1
75 more
than
95
50 
settle
50 
settle
AY-X108E
No.
Hz
Operation 
mode
Cool
(Max.)
Heat
(Max.)
Cool Heat
1
2
3
4
3-way valve
pressure
(kg/cm
2
G)
98˚C
43˚C
14˚C
13˚C
4.6
104˚C
2˚C
35˚C
7˚C
17.6
73˚C
42˚C
16˚C
17˚C
6.5
58˚C
3˚C
31˚C
3˚C
12.3
94 more
than
100
50 
settle
50 
settle
AY-X138E
No.
Hz
Capillary tube
O.D I.D. L
ø2.7 ø1.5 800
AY-X108E
Dimension of Capillary tube
Capillary tube A
O.D I.D. L
ø2.7 ø1.6 500
Capillary tube B ø2.7 ø1.7 300
AY-X138E