AH/AU-X108E
AY/AE-X108E
AH/AU-X138E
AY/AE-X138E
37
Figure P-5 At Cooling for AY-X138E
Figure P-6 At Heating for AY-X138E
25 30 35 40
3.2
3.4
3.6
3.8
4.0
10
12
14
1000
1100
1200
1300
Cooling capacity(kW)
Outside air temp.(˚C)
Input(W)
Outlet air temp.(˚C)
1) Indoor fan speed: Hi
2) Vertical adjustment louver "45˚", Horizontal adjustment louver "front" 
3) Indoor air temp. : Cooling 27˚C
NOTE:
(Running frequency: 77Hz)
Figure P-4. At Cooling for AH-X138E
-5 0 5 10
3.0
3.5
4.0
4.5
5.0
5.5
35
30
40
45
1300
1200
1400
1500
1600
(Running frequency: 100Hz)
Heating capacity(kW)
Outside air temp.(˚C)
Input(W)
Outlet air temp.(˚C)
25 30 35 40
3.2
3.4
3.6
3.8
4.0
10
12
14
1000
1100
1200
1300
(Running frequency:79Hz)
Cooling capacity(kW)
Outside air temp.(˚C)
Input(W)
Outlet air temp.(˚C)