AY/AE-A079E
AY/AE-A099E
22
Cycle temperature and service port pressure
ISO Cooling and Heatpump condition
(at 220V REFRIGERANT PIPE LENGTH 7.5 m)
Dimension of Capillary tube
ISO Cooling and Heatpump condition
O.D. I.D. L
Capillary tube A
Capillary tube B
MODEL
ø 2.7 ø 1.5
ø 1.4
800
600ø 2.7
O.D. I.D.
AE-A079E AE-A099E
L
ø 2.7 ø 1.5
ø 1.5
700
700ø 2.7
AY-A079E
78˚C 65˚C
43˚C 2˚C
11˚C 33˚C
8˚C 1 ˚C
0.52MPa 1.49MPa
AY-A099E
80˚C 84˚C
Cooling Heating Cooling Heating
44˚C 1˚C
11˚C 35˚C
6˚C 3 ˚C
0.47MPa 1.75MPa
Service port pressure
Model
NO. Condition
1
2
3
4
Gauge pressure
Indoor side
Outdoor side
Temperature (˚C) Temperature (˚C)Relative humididity (%) Relative humididity (%)
27 47 35 40
20 37 7 87
Cooling
Heating