
Do you have a question about the Sharp AY-X9PSR and is the answer not in the manual?
| Power Supply | 220-240 V, 50 Hz |
|---|---|
| Outdoor Unit Weight | 28 kg |
| Refrigerant | R32 |
| Type | Split System |
| Outdoor Unit Dimensions (W x H x D) | 780 x 540 x 269 mm |
Detailed specifications for AY-X9PSR/AY-X12PSR air conditioners, including electrical data, compressor, and fan system.
Provides external dimensions and diagrams for the indoor unit of the air conditioner.
Provides external dimensions and diagrams for the outdoor unit of the air conditioner.
Wiring diagram for the indoor unit, showing electrical connections and components.
Wiring diagram for the outdoor unit, detailing electrical connections and components.
Lists electrical parts for AY-X9PSR/AE-X9PSR units with codes and remarks.
Lists electrical parts for AY-X12PSR/AE-X12PSR units with codes and remarks.
Block diagram of the indoor unit's control system, detailing its functional blocks and connections.
Block diagram of the outdoor unit's control system, detailing its functional blocks and connections.
Electronic control circuit diagram for the indoor unit's microcomputer system.
Shows the printed wiring board layout for the indoor unit.
Electronic control circuit diagram for the outdoor unit's inverter module board.
Schematic diagram of the power supply board's electronic control circuit.
Shows the printed wiring board layout for the inverter module board.
Layout diagram of the power supply board's printed wiring.
Explains the 3-minute delay for compressor restart to protect the unit.
Prevents compressor overheat by controlling frequency and shutting down if necessary.
Protects unit from over/under voltage by stopping operation.
Prevents overcurrent by reducing compressor frequency or stopping the unit.
Prevents indoor evaporator freezing by stopping the compressor and displaying code P5.
Prevents outdoor unit overheat by controlling frequency and stopping the compressor.
Shuts down the outdoor unit if IPM temperature or current is too high.
Explains the defrosting process and conditions controlled by the microprocessor.
Details how AUTO mode automatically selects settings based on room temperature.
Instructions on adjusting vertical and horizontal airflow direction.
Describes temperature setting ranges and adjustments for different modes.
Explains how drying mode adjusts room temperature and fan speed.
Explains how PFC circuit controls compressor voltage and speed.
Details protective device functions, detection periods, reset conditions, and error displays.
Describes thermistor errors and their effects on indoor unit operation modes.
Lists protective functions related to outdoor thermistors and their error conditions.
Provides temperature and resistance characteristics for indoor/outdoor thermistors.
Troubleshooting guide for when the indoor unit fails to turn on.
Troubleshooting guide for when the indoor unit fan fails to operate.
Troubleshooting guide for when the indoor unit fan speed does not change.
Troubleshooting steps when the remote control signal is not received.
Troubleshooting steps when the vane does not move.
Troubleshooting steps when the compressor does not start.
Flowchart for diagnosing defective outdoor unit IPM or compressor issues.
Flowchart for diagnosing DC Over Current errors.
Lists failure codes, indicator status, and LED display for indoor units.
Lists failure codes and fault messages for outdoor power supply PCB.
Lists fault messages and blink times for outdoor IPM failures.
Lists protection types, function indicator flashes, and digital LED displays.
Troubleshooting for E1/E2 display codes related to thermistor faults.
Troubleshooting for E6 display code related to indoor fan motor fault.
Troubleshooting for E3, E7, E8 codes related to outdoor sensors.
Troubleshooting for EA display code related to current sensor fault.
Troubleshooting for EC display code related to outdoor communication faults.
Troubleshooting for EU display code related to voltage sensor fault.
Troubleshooting for EP display code related to compressor temperature switch fault.
Troubleshooting for P1 display code related to over/undervoltage protection.
Troubleshooting for E9 code, often following P0 or P9, related to IPM faults.
Troubleshooting for EE display code related to EEPROM fault.
Troubleshooting for E0/E5 codes related to indoor/outdoor communication faults.
Troubleshooting for P4 code related to discharge overtemperature protection.
Troubleshooting for P2 code related to overcurrent protection.
Troubleshooting for P5 code related to subcooling protection.
Troubleshooting for P6 code related to overheating protection under cooling mode.
Troubleshooting for P7 code related to overheating protection under heating mode.
Troubleshooting for P8 code related to outdoor air temperature protection.
Troubleshooting for P9 code related to IPM faults.
Schematic diagram illustrating the refrigeration cycle of the air conditioner.
Specifies standard conditions for cooling and heating operation.
Lists temperature and pressure details for the 3-way valve in different modes.
Cooling and heating performance curves for AY-XP9PSR/AE-XP9PSR models.
Cooling and heating performance curves for AY-X12PSR/AE-X12PSR models.
Step-by-step instructions for disassembling the indoor unit of the air conditioner.
Step-by-step instructions for disassembling the outdoor unit of the air conditioner.
Instructions for disassembling the control box of the air conditioner.
Important safety precautions to follow during air conditioner installation.
Instructions for installing the mounting plate and making the piping hole.
Steps for connecting refrigerant pipes and setting up the indoor unit.
Instructions for connecting the electrical cable to the indoor unit.
Instructions for connecting and routing the drain hose for indoor unit.
Instructions for firmly fastening the outdoor unit with bolts.
Steps for connecting refrigerant pipes, including flaring and tightening.
Procedure for removing air from the refrigerant system using a vacuum pump.
Instructions for connecting the electrical cable to the outdoor unit.
Procedure for performing a test run of the air conditioner.
Procedure for collecting refrigerant into the outdoor unit for removal.
Instructions on how to use the remote control, including battery loading.
Step-by-step guide to basic operation using the remote control buttons.
Instructions on adjusting vertical and horizontal airflow direction.
Explanation of the full power operation mode for rapid cooling or warming.
Instructions for setting TIMER OFF and TIMER ON functions.
Provides simple tips for saving energy when using the air conditioner.
Important notes on operating conditions, power failure, and heating defrosting.
Overview of the parts guide structure for indoor and outdoor units.
Exploded view diagram of indoor unit parts with numbering.
Part list for AY-X9PSR indoor unit, including part numbers, names, and quantities.
Part list for AY-X12PSR indoor unit, including part numbers, names, and quantities.
Lists accessory parts such as remote control and manuals.
Lists packing materials for indoor units (cartons, foaming).
Exploded view diagram of outdoor unit parts with numbering.
Part list for AE-X9PSR outdoor unit, including part numbers, names, and quantities.
Part list for AE-X12PSR outdoor unit, including part numbers, names, and quantities.
Loading...