Cooling Capacity | 2.8 kW |
---|---|
Heating Capacity | 3.6 kW |
Refrigerant | R32 |
Weight (Outdoor Unit) | 28 kg |
Power Supply | 220-240 V, 50 Hz |
Type | Split System |
Dimensions (Outdoor Unit) | 780 x 540 x 269 mm |
Unit must be installed by a licensed contractor and operate on 220-240V AC, 50Hz.
Turn off the circuit breaker before maintenance, cleaning, or extended periods of non-use.
If abnormal operation (e.g., burning smell) occurs, turn off the unit immediately and disconnect power.
Keep combustible materials at least 1.5 meters away from the units to prevent fire or explosion.
Do not attempt self-repair; contact a Sharp Approved Service Centre for repairs due to risk of electric shock or fire.
Do not cut or damage power and control cords; contact a contractor if damaged.
Do not insert hands or objects into air intake or outlet vents to prevent injury or damage.
Splashing water on the air conditioner can cause electric shock and malfunction.
Explains the function of temperature adjustment and fan speed selection buttons on the remote control.
Details how to turn the unit on/off and cycle through operating modes (AUTO, COOL, DRY, FAN, HEAT).
Explains how to operate the unit using the manual switch on the main unit when the remote control is lost or damaged.
Important safety cautions for cleaning, including turning off power and avoiding direct liquid spray.
Lists checks for unit not running, including power, circuit breaker, and wiring issues.
Provides checks for poor cooling/heating efficiency, such as temperature settings, obstructions, and fan speed.
Lists critical situations requiring immediate shutdown, power disconnection, and contractor contact for safety.
Emphasizes installation by authorized contractors and the need for a dedicated circuit and circuit breaker.
Details electrical safety requirements, including dedicated circuits, circuit breakers, and minimum distances from combustible surfaces.
Explains the importance of proper earthing for the unit (Type I appliance) and the yellow-green wire.
Emphasizes that all interconnecting wiring must be done by a licensed electrical contractor according to AS/NZS3000.
Instructions for removing the access plate, connecting power and signal wires, and securing them.
Details the process for air purging and conducting a leakage test using a manifold valve and vacuum pump.
Lists items to check after installation to prevent malfunctions, such as fixing firmness and refrigerant leakage.
Outlines the steps for performing a test operation, including switching on power and checking modes.
Guarantees rectification of defects due to faulty materials or workmanship within 60 months of original purchase.
Lists warranty conditions, including installation compliance, serviceable area, and original installation.
Details situations and causes not covered by the warranty, such as misuse, neglect, or unauthorized alterations.
Provides contact details for Sharp customer care in Australia, including website and phone number.
Provides contact details for Sharp customer services in New Zealand, including website, dealer contact, and phone numbers.