ADDITIONAL
NOTES
ON
OPERATION
OPERATING
TEMPERATURE
RANGE
INDOOR
TEMP.
[OUTDOOR
TEMP.|
°
>,
Dulltin
protective
device
might
prevent
the
unit
from
operating
when
used
out
of
this
range.
¢
Condensation
might
form
on
the
air
outlet
when
the
unit
operates
continuously
in
the
COOL
or
the
DRY
mode
when
the
humidity
is
over
80
percent.
upper
limit
COOLING
lower
limit
upper
limit
HEATING
lower
limit
L
D.B.=Dry-bulb
W.B.
=
Wet-bulb
PREHEATING
FUNCTION
In
the
HEAT
operation,
the
indoor
fan
might
not
start
for
two
to
five
minutes
after
the
unit
is
turned
on
to
prevent
the
air
from
circulating
before
the
unit
is
sufficiently
warmed
up.
DE-ICING
FUNCTION
¢
When
ice
forms
on
the
heat
exchanger
in
the
outdoor
unit
during
the
HEAT
operation,
an
automatic
de-icer
provides
heat
for
about
5
to
10
minutes
to
remove
the
ice.
During
de-icing,
the
inside
and
outside
fans
stop
operating.
¢
After
de-icing
is
completed,
the
unit
automatically
resumes
operation
in
the
HEAT
mode.
HEATING
EFFICIENCY
*
The
unit
employs
a
heat
pump
that
draws
heat
from
the
outside
air
and
releases
it
into
the
room.
The
outside
air
temperature
therefore
greatly
affects
the
heating
efficiency.
*
If
low
outside
temperatures
adversely
affect
the
heating
efficiency,
use
an
additional
heater.
*
It
takes
time
to
warm
up
and
heat
the
entire
room
because
this
unit
employs
a
forced
air
circulation
design.
TIPS
ON
SAVING
ENERGY
Below
are
some
simple
ways
to
save
energy
when
you
use
your
air
conditioner.
SET
THE
CORRECT
TEMPERATURE
*
Setting
the
thermostat
1°C
higher
in
COOL
mode,
and
2°C
lower
in
HEAT
mode
than
the
desired
temperature
will
result
in
a
10
percent
saving
in
electricity.
*
Setting
the
temperature
colder
than
necessary
during
cooling
will
result
in
excess
power
consumption.
KEEP
OUT
DIRECT
SUNLIGHT
AND
DRAFTS
*
Keeping
out
direct
sunlight
when
cooling
will
aid
in
reducing
the
power
consumption.
*
Close
the
windows
and
doors
when
heating
and
cooling
the
room.
SET
PROPER
AIR
FLOW
DIRECTION
TO
OBTAIN
THE
BEST
AIR
CIRCULATION
KEEP
FILTER
CLEAN
TO
ENSURE
THE
MOST
EFFICIENT
OPERATION
MAKE
MOST
OF
THE
TIMER
OFF
FUNCTION
UNPLUG
THE
POWER
CORD
WHEN
THE
UNIT
IS
NOT
TO
BE
USED
FOR
AN
EXTENDED
PERIOD
¢
The
indoor
unit
still
consumes
a
small
amount
of
power
when
it
is
not
operating.
E-2
<=
a
©
Zz
Wi

Other manuals for Sharp AY-X095E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp AY-X095E and is the answer not in the manual?

Sharp AY-X095E Specifications

General IconGeneral
BrandSharp
ModelAY-X095E
CategoryAir Conditioner
LanguageEnglish

Related product manuals