Model
AY-X12MCJAE-X
12MCJ
Function COOLING HEATING
Rated Voltage 220-240V~
Frequency(Hz) (High/Standard *) 50HZ
Total Capacity (W) (High/Standard /min*):
Total Capacity (Btu/h) (High/ Standard /imin*):
4000/3500/ 1233(W)
13600/12000/4200(Btu/h)
4100/3850/830 (W)
14000/13000/2830(Btu/h)
Power Input (W) (High/ Standard*) 1400/1000/262 1450/1066/233
Rated Input (W) (High/ Standard *) 1400 1450
Rated Current (A) (High/ Standard *) 6 6.3
Air Flow Volume (m
3
/h)
(H/M/L)**
450
Dehumidifying Volume (l/h) 1.2
EER / C.O.P (W/W) 3.51 3.61
Energy Class A
Model of Indoor Unit
AY-X12MCJ
Fan Motor Speed (r/min) (S/H/M/L) 1400/1150 /1050l/900
Output of Fan Motor (w) 10
Fan Type-Piece Cross flow fan – 1
Diameter-Length (mm)
φ85 X 668
Evaporator Aluminum fin-copper tube
Row-Fin Gap(mm) 2-1.5
Coil length (l) x height (H) x coil width
(L)
657X285X25.4
Swing Motor Model MP28VB
Output of Swing Motor (W) 2
Fuse (A) PCB 3.15A Transformer 0.2A
Sound Pressure Level dB (A)
(S/H/M/L)
42/ 38 / 30/28
Sound Power Level dB (A)
(S/H/M/L)
53/ 47/ 40/38
Dimension (W/D/H)( mm) 872X178X283
Dimension of Package
(W/D/H)( mm)
935x260X375
Indoor
unit
Net Weight /Gross Weight (kg)
12/15
- 26 -