LC-80LE642U
5 – 11
8.2.2 Factory Mode
8.2.3 Composite N358 signal/tuner adjustment
8.2.4 Component 33K signal adjustment
8.2.5 Analog RGB signal adjustment
8.2.6 Tuner/V-CHIP adjustment
Adjustment point Adjustment conditions Adjustment procedure
Factory Mode Shift to Adjustment mode by Special R/C code.
Adjustment point Adjustment conditions Adjustment procedure
1 Setting N358 signal
US-10ch
• Input N358 color bar (color saturation 75%) signal to composite input.
• Input In-house broadcasting signal (10ch) to tuner.
2 Running Auto-Adjustment
Program
Select [ N358 ALL ADJ(INPUT2)] then press ENTER.
Adjust is finish at display [ N358 ALL ADJ (INPUT2) OK].
Adjustment point Adjustment conditions Adjustment procedure
1 Setting 1080i signal • Input 100% color bar signal to Component input.
2 Running Auto-Adjustment
Program
Select [ COMP33k ADJ(INPUT1)] then press ENTER.
Adjust is finish at display [ COMP33k ADJ(INPUT1) OK].
Component 15K adjustment will be done automatically by set itself.
(AUTO CLAMP 1, parameter will be copy from 33K data)
Adjustment point Adjustment conditions Adjustment procedure
1 Setting Signal: XGA
(1024x768) 60Hz
SYNC: HV separate
• Input 100% color bar to PC input.
2 Running Auto-Adjustment
Program
Select [ ANALOG RGB ADJ] then press ENTER.
Adjust is finish at display [ ANALOG RGB ADJ OK].
Adjustment point Adjustment conditions Adjustment procedure
1 Setting NTSC RF signal
US-7(AIR)ch
• Input NTSC signal to RF Antenna.
2 Running Auto-Adjustment
Program
Select [ VCHIP TEST(*07ch)] then press ENTER.
(*Select In-house broadcasting signal channel)
Adjust is OK at display [ VM-OK].
(Adjust is NG at display VM-NG)
[Video input signal] [In-house US-10ch]
100% white 100% white
0% black
Color saturation: 75%
100% white 0% black
1080i
100% color bar
Color saturation: 100%
100% white 0% black
XGA (1024x768)
100% color bar