MX3500N SIMULATION 7 – 30
24-30
Purpose
Data clear
Function (Purpose)
Used to initialize the administrator pass-
word.
Section
—
Item
Clear
Operation/Procedure
1) Press [EXECUTE] button.
2) Press [YES] button.
The administrator password is initialized.
24-31
Purpose
Data clear
Function (Purpose)
Used to initialize the service mode pass-
word.
Section
—
Item
Clear
Operation/Procedure
1) Press [EXECUTE] button.
2) Press [YES] button.
The service mode password is initialized.
25
25-1
Purpose
Operation test/Check
Function (Purpose)
Used to check the operations of the devel-
oping section.
Section
Process (Developing section)
Item
Operation
Operation/Procedure
1) Select the process speed with [MIDDLE], [LOW] and [HIGH]
(MX-4500N/4501N only) buttons.
2) Press [EXECUTE] button.
The developing motor and the OPC drum motor rotate for 3
min and the detection level of the toner density sensor is dis-
played.
25-2
Purpose
Setting
Function (Purpose)
Used to make the initial setting of toner
concentration when replacing developer.
Section
Process (Photoconductor/Developing/
Transfer/Cleaning)
Item Adjustment
Operation/Procedure
1) Select the adjustment target with the buttons on the touch
panel.
2) Press [EXECUTE] button.
The toner concentration sensor makes sampling of toner con-
centration to display the detection level.
NOTE: When the above operation is interrupted on the way, the
reference toner concentration level is not set. Also when
error code of EE-EC, EE-EL or EE-EU is displayed, the ref-
erence toner concentration level is not set normally.
SCAN TO HDD_CL Scan to HDD record quantity (COLOR)
SCAN TO HDD_2CL Scan to HDD record quantity (2-color)
SCAN TO HDD_SGL Scan to HDD record quantity (Single color)
0
RE YOU SUR E?
YES NO
TCD_K Toner concentration sensor K
TCD_C Toner concentration sensor C
TCD_M Toner concentration sensor M
TCD_Y Toner concentration sensor Y
TCV_K Toner concentration control voltage K
TCV_C Toner concentration control voltage C
TCV_M Toner concentration control voltage M
TCV_Y Toner concentration control voltage Y
Display items Item descriptions
Display
range
Default
value
AT DEVE ADJ_L_K Automatic developer
adjustment value at low
speed
1 – 255 128
AT DEVE ADJ_L_C 1 – 255 128
AT DEVE ADJ_L_M 1 – 255 128
AT DEVE ADJ_L_Y 1 – 255 128
AT DEVE ADJ_M_K Automatic developer
adjustment value at
middle speed
1 – 255 128
AT DEVE ADJ_M_C 1 – 255 128
AT DEVE ADJ_M_M 1 – 255 128
AT DEVE ADJ_M_Y 1 – 255 128