2
 The cable from the appliance is equipped with 
3-wire.
IMPORTANT: Use the 3-wire cable from Home Power Supply 
where local codes permit a 3-wire connection.
Use the 4-wire cable from Home Power Supply where local codes 
do not allow grounding through neutral.
Connecting to a 3-wire power OR 4-wire power supply cable 
electrical system
1.  Disconnect the power supply.
2.  In the circuit breaker, fuse box, or junction box, connect appliance 
and power supply cable wires as shown below (3-wire, Figure 1; 
4-wire, Figure 2).
3.  Circuit breaker fuse rating must be above 40 A, and wire should 
be 2/8 or 3/8 copper.
4.  Minimum acceptable size of conductors should be no less than 
10AWG, copper only, and no less than 167°F.
5.  A wire-binding screw or stud used in the wire terminal should 
be 10 or larger.
 
•  The electrical power to the cooktop must be shut off while line 
connections are being made. Failure to do so could result in 
serious injury or death.
•  An extension cord must not be used with this appliance. Such 
use may result in a re, electrical shock or other personal injury.
Cable from Power Supply
3-Wire Cable from Home Power Supply
Cable from Appliance
Red Wire
Red Wire
Green Wire
(Grounding)
Black Wire
Junction Box
Figure 1
Cable from Power Supply
4-Wire Cable from Home Power Supply
Cable from Appliance
Red Wire
Red Wire
Green Wire
(Grounding)
White Wire
Black Wire
Junction Box
Figure 2
 The cooktop conduit wiring is approved for cop-
per wire connection only, if you have aluminum house wiring, use 
only special connectors which are approved for joining copper and 
aluminum wires conform with local codes and ordinances. Follow the 
electrical connector manufacturer’s recommended procedure closely.
IMPORTANT - Save for the local electrical inspector's use.