6
SJ-48H-S
SJ-51H-S
SJ-55H-S
COIL POSITION OF COMP.
Aux. coil
Common
Main coil
LIST OF ELECTRICAL PARTS
ITEMS TYPE NAME RATING SPECIFICATIONS
F-Thermostat MM1-8025 250V 3A (At normal notch)ON/OFF : -17/-22˚C
Defrost thermo. US-602S 250V 8A Open/Close : 10/1˚C
Thermo. fuse MGT4A50072 250V 10A Working temp. : 72˚C
Fan motor 3R00044B 220 - 240V 50Hz Working with ø100 fan
Defrost heater MM6-4015 at 230V 150W
(220-240V)
Door switch MM1-7B01 250V 0.25A 3 terminals push-button type
Damper thermostat MM1-6129 Open/Close : 0.5/-4˚C
Defrost timer TMDF904FD2 220-240V Integration type
50Hz Cycle time : 10.8 hours(50Hz)
Delay time : 4.3 min.(50Hz)
Lamp socket 250V 1A E-12(Hard plastic body type)
Lamp 240V 10W E-12
SJ-51H, SJ-55H
Compressor GL-99BH 220-240V/50Hz Cooling capacity : 210kcal/h(50Hz)
Main/Aux. coil : 8.5/15.0(at 20˚C)
Starting relay PTH490D35AS 14Ω±20%
140N320-T
Protector 4TM308NFBYY Open/ Close : 120/61˚C
Running capacitor 400VAC 6µF
SJ-48H
Compressor GL-90BH 220-240V/50Hz Cooling capacity : 192kcal/h(50Hz)
Main/Aux. coil : 8.8/17.7(at 20˚C)
Starting relay PTH490D35AS 14Ω±20%
140N320-T
Protector 4TM276NFBYY Open/ Close : 120/61˚C
Running capacitor 400VAC 6µF