SYSTEM-CD555ZT
CD
SECTION
"Track
skipping
and/or
no
TDC(Table
Of
Contents)
may
be
caused
by
a
build
up
of
dust
other
foreign
matter
on
the
laser
pickup
lens.
Before
attempting
any
adjustment
make
certain
that
the
lens
is
clean.
If
not,
clean
it
as
mentioned
below.ā€
1.
Turn
the
power
off.
2.
Gently
clean
the
lens
with
a
lens
cleaning
tissue
and
a
small
amount
of
isopropyl
alcohol.
Note:
Do
not
touch
the
lens
with
the
bare
hand.
1.
Preparation
for
Adjustment
Setting
the
Test
Mode
TEST
MODE
0
Pressing
simultaneously
the
All
the
segments
light
for
1.5
ā€œCLEARā€
and
ā€œCALLā€
buttons,
set
|
seconds
and
then
the
Test
Mode
the
function
switch
to
ā€œCDā€.
0
indication
appears.
ā€œ|
F
=
=]
TEST
MODE
1
TEST
MODE
2
TEST
MODE
3
TEST
MODE
4
TEST
MODE
5
After
TEST
MODE
5
the
PLAY
button
is
inoperative.
Even
when
it
is
pressed
(6th
time),
key
entry
is
not
accepted.
In
TEST
MODE
0
press
once
the
PLAY
button.
(1st)
Laser
lights.
In
TEST
MODE
1
press
once
the
PLAY
button.
(2nd)
Focus
start
(Servo
ON)
Disc
rotates.
(Spin
servo
ON)
(Use
the
disc.)
In
TEST
MODE
2
press
once
the
PLAY
button.
(3rd)
In
TEST
MODE
3
press
once
the
PLAY
button.
(4th)
Tracking
servo
ON
(Use
the
disc.)
Track
No.
and
time
are
indicated.
(Use
the
disc.)
In
TEST
MODE
4
press
once
the
PLAY
button.
(5th)
*Unless
the
CD
lid
switch
SW961
is
tumed
on,
the
test
mode
is
not
set.
Button
Operation
in
Test
Mode
14.
When
the
STOP
button
is
pressed,
all
operations
stop.
At
this
time
the
optical
pickup
does
not
slide,
and
TEST
MODE
0
is
displayed.
2.
While
the
UP/CUE(DOWN/REVIEW)
button
is
pressed,
the
optical
head
moves
from
inside
to
outside
or
from
the
outside
to
the
inside.
*
Operation
is
possible
both
during
playing
and
stopping.
e
While
this
operation
is
executed,
the
TEST
MODE
indication
does
not
change.
After
the
optical
pickup
is
slided
from
the
outside
to
the
inside
and
the
optical
pickup
switch
is
turned
on,
the
slide
stops.
(At
the
same
time
TEST
MODE
Ois
set.)
Notes:
1.
Any
buttons
other
than
those
specified
above
are
invalid.
2.
Before
operation
be
sure
to
connect
all
the
connectors.
442
SYSTEM-CD5552ZT
Servo
Unit
All
the
semivariable
resistors
must
be
set
in
the
mechanical
center
position.
Adjusting
Parts
Instrument
Connection
i
Set
TEST
MODE
0,
and
move
the
pickup
to
the
center
i
Set
Test
MODE
1
(make
sure
that
the
laser
lamp
lights)
After
loading
a
disc,
set
to
TEST
MODE
2.
(Check
to
see
that
focus
servo
is
ON.:
The
disc
does
not
rotate,
and
a
whining
sound
is
heard.)
Set
TEST
MODE
3
(Spin
servo
is
turned
on,,
and
the
disc
rotates)
i
|
i
Tracking
error
balance
adj.
NVRA1
*4
(See
Fig.
12-1)
Pin
6
(1/2Vcc)
and
pin
4
(TG1)
of
TP751
Set
TEST
MODE
4
(Tracking
servo
is
turned
on.)
|
Check
the
HF
signal
waveform
_
Amplitude
of
1.5-2.0
Vp-p
|
Pin
3
(HF)
and
pin
7
(GND)
of
'
|
(See
Fig.
12-2.)
|
TP751
Focus
gain
adj.
VR751
Adjust
to
obtain
the
same
waveform
|
Pin
1
(FG1)
and
pin
5
(FG2)
of
|
on
CH1
and
CH2.
*2
TP751
and
ground
(The
relay
circuit
|
is
used.)
|
Adjust
to
obtain
the
same
waveform
|
Pin
4
(TG1)
and
pin
2
(TG2)
of
i
|
Tracking
gain
adj.
VR750
on
CH1
and
CH2.
*3
TP751
and
ground
(The
relay
circuit
|
is
used.)
Check
again
the
HF
signal
waveform.
'
Set
TEST
MODE
5,
and
make
sure
that
track
No.
and
time
are
displayed.
Stick
black
tape
on
the
disc,
and
play
that
section
(Fig.
13-1).
(Any
mode
other
than
the
test
mode
is
acceptable.)
E28.
Focus
offset
adj.
VR700
*4
(Fig.
13-2)
Pin
6
(1/2Vcc)
and
pin
1
(FG1)
of
:
TP751
*5
Tracking
offset
adj.
VR710
Pin
6
(1/2Vcc)
and
pin
4
(TG1)
of
TP751
*7
*
4.
Adjust
to
obtain
vertically
symmetrical
waveform
(Fig.
12-1)
with
respect
to
reference
DC
level.
The
reference
level
is
1/2Vcc.
(Amplitude
of
0.5
to
1.5
Vpp)
*
2.
Input
oscillation
frequency:
1.3
kHz,
100
mV
rms
*
3.
Input
oscillation
frequency:
1.5
kHz,
300
mV
rms
*
4.
Watch
the
monitor.
Adjust
so
that
the
error
waveform
is
uniform
and
minimum
(Fig.
13-2)
and
the
audio
output
is
played
properly
without
noise
(track
jump
noise)
and
free
from
skips
and
pauses.
*
5.
The
appropriate
measuring
range
of
the
oscilloscope
is
50mV
and
0.5mS.
Connect
the
trigger
to
pin
14
(HFOK)
of
CNS700.
Trigger
the
coupling
at
DC
and
(—)
slope.
Observe
the
waveform
in
the
normal
trigger
mode.
*
6.
Watch
the
monitor.
Adjust
so
that
the
error
waveform
is
uniform
and
minimum
(Fig.
13-2)
and
the
audio
output
is
played
properly
without
noise
(track
jump
noise).
*
7.
The
appropriate
measuring
range
of
the
oscilloscope
is
0.1V
and
0.5mS.
The
trigger
is
the
same
as
*5.
(Reference)
When
the
noise
element
of
the
error
waveform
is
large
and
unclear,
observe
the
waveform
through
the
low-pass
filter
(Fig.
13-3).
|
SSR
RER
MANNS
DL
ARR
RARRRA
OP.
O.O
OP OP
OG.
AK
,
Vp-p
Reference
FarERETUTNINA
Mm
|
Syma
evel
—
AT
ALLARERARV
A
uP
anc
down
1/2
Vec
et
ee
—0.5~1.5Vp-p
ms
verter
deed
Pin
7
Figure
12-1
Figure
12-2
2405

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp SYSTEM-CD555ZT(GY) and is the answer not in the manual?

Sharp SYSTEM-CD555ZT(GY) Specifications

General IconGeneral
BrandSharp
ModelSYSTEM-CD555ZT(GY)
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals