14
shall be carried out prior to returning the compressor to the suppliers. Only
electric heating to the compressor body shall be employed to accelerate
this process. When oil is drained from a system, it shall be carried out safely.
Technical specication
Model UL-C10EA-W UL-C12EA-W UL-Y12EA-W
Power Supply 220 – 240V AC, 50Hz 220 – 240V AC, 50Hz 220 – 240V AC, 50Hz
Energy Eciency Class
Cooling A+ A A
Heating N/A N/A A+
Running Power Consumption
Cooling (W) 935 1345 1345
Heating (W) N/A N/A 1190
Standby Power Consumption (W) 0,5 0,5 0,5
Cooling Capacity (W) 2900 3520 3520
Heating Capacity (W) N/A N/A 3100
Noise Level dB(A) (Fan speed: High/Medium/Low) 65/64/62 65/64/62 65/64/62
Air Flow (High/Medium/Low) (m³/h) 385/355/325 385/355/325 385/355/325
Operating Temperature Range (°C) 16 ~ 30 16 ~ 30 16 ~ 30
Room Size (m²) 13 ~ 19 16 ~ 23 16 ~ 23
Size (W x D x H in mm) 393 x 425 x 804 393 x 425 x 804 393 x 425 x 804
Weight (kg) 32,5 34,5 35,0
Refrigerant R290 R290 R290
Technical specications are subject to change without notice.
17 / 98