VC-MH80
VC-MH90
PB
CHROMAenvelope
(TP2201)
I
-.
It--
-..-_-
cl-i-1
,
CH-2
Head switching pulse
(TP2202)
Figure
4-38.
7. Adjustment of AIC head height and azimuth
a) Connect an oscilloscope to the audio output
terminal.
b) Use the alignment tape and play back its
audio
.6
kHz
signal (monoscope pattern for
video signal). Adjust the azimuth adjusting
screw to obtain the maximum audio output
on an oscilloscope. (See Figure 4-39.)
c) Use the alignment tape and play back its
audio
1
kHz
signal (colour bar for video signal)
and slowly rotate the A/C head height adjust-
ing nut with the special box driver to obtain
the maximum audio output.
d) Perform the adjustment in b) again.
e) After this adjustment, apply
glyptal
to the
screws and nuts to fix them.
Azimuth
screw
Box driver
AK
head herght
adjusting screw
nut
Figure
4-39.
Figure
440.
8. Adjustment of tape drive train and X-Position.
a) Connect the oscilloscope to the test points
(TP2201) for
PB
CHROMA envelope output.
Set the synchronism of the oscilloscope to EXT.
The
PB
CHROMA signal is to be triggered by
the head switching pulse
(TP2202).
b) Play back the tape drive train alignment tape.
c) Push the
(+)
or (-) button to change the enve-
lope waveform from MAX to MIN, and MIN to
MAX. Adjust the guide roller’s height on the
supply and take-up sides with an adjusting
screw driver, to obtain an envelop waveform
that is as flat as possible.
d)
If the tape is above or below the helical lead,
the
PB
CHROMA waveform will take the shape
shown in Figure 4-41.
e) Adjust for maximum flatness of the envelope
as the step 6, e) in page 23.
When the tape is above the helical lead.
When the tape is below the helical lead.
Supply side
Take-up side
Supply side
Take-up side
Supply side guide
Take-up side guide
Supply side guide
Take-up side guide
roller rotated in
roller rotated in
roller rotated in
roller rotated in
clockwise direction clockwise direction
counterclockwise
counterclockwise
direction (raises guide
direction (raisesguide
Adjustment
(lowers guide roller) to (lowers guide roller) to
roller) to make the
flatten envelope. flatten envelope.
roller) to make the
tape float above the
tape float above the
helical lead.
helical lead. The supply
The take-up side guide
side guide roller is
roller is then rotated in
then rotated in the
the clockwise direction
clockwise direction to
to flatten the
flatten the envelope.
envelope.
L
Figure
441.
24