EasyManua.ls Logo

Sharp XL-520H - Page 10

Sharp XL-520H
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
XL-520H,520E/CP-520,520E
– 10 –
Figure 10-2
Figure 10-3
1. This CD unit need adjustment as follow.
CD SECTION
Figure 10-4
CD Test Mode
Adjustment Part
Value/Adjusting Method
Instrument Connection
Step 1 VR803 (Focus Offset) DC + 40 mV (FEI>VRO) FEI (R826) and VRO
(1-Pin of TP801)
Step 4 VR802 (Tracking Error Balance) *1 (See Fig. 10-2) TSO (3-Pin of TP801)
and VRO (1 Pin of TP801)
*1: Adjust to obtaiin vertically symmetrical waveform (Fig. 10-2) with respect toreference DC level. The reference level is VRO
(Approx DC 2.1V).
2. This CD unit have the following automatic adjustment function. Automatic adjustment item.
2-1: Focus Servo Gain (Fig. 10-3)
Focus Gain Adjustment is performed when disc is changed.
2-2: Tracking Servo Gain (Fig. 10-4)
Tracking Gain Adjustment is performed when disc is changed and disc is playbacked.
TSO
VRO
1
SYMMETRICAL
UP AND DOWN
FET
FSO
1
2
TSO
TS2O
1
2
Figure 10-1 ADJUSTMENT POINTS
VR802 VR803
TP801
TRACKING
ERROR
BALANCE
FOCUS
OFFSET
T
S
O
N
C
V
R
O
321
321
CD SERVO PWB