EasyManua.ls Logo

Shenzhen PM-9000 Express - User Manual

Shenzhen PM-9000 Express
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
PM-9000 Express
Patient Monitor
Service Manual
Question and Answer IconNeed help?

Do you have a question about the Shenzhen PM-9000 Express and is the answer not in the manual?

Summary

Copyright Statement

Responsibility on the Manufacturer Party

Outlines the manufacturer's responsibilities for the equipment's safety, reliability, and performance.

Warranty

Safety, Reliability and Performance

Specifies conditions under which Mindray is not responsible for safety, reliability, and performance.

Return Policy

Return Procedure

Details the required procedure for returning a unit to Mindray for service.

Company Contact

Provides contact information for the manufacturer, Shenzhen Mindray Bio-Medical Electronics Co., Ltd.

Safety Precautions

Meaning of Signal Words

Defines signal words like DANGER, WARNING, and CAUTION used in the manual.

Meaning of Safety Symbols

Explains the meaning of various safety symbols used in the manual.

Symbols

Chapter 1 About the Product

1.1 Introduction

Introduces the PM-9000 Express patient monitor, its features, and portability.

1.2 Application

Discusses the importance and usage of patient monitors in medical settings.

1.3 Environment

Details the operating and storage environmental specifications for the monitor.

Chapter 2 Principles

2.1 General

Provides a general overview of the patient monitor's functional parts.

2.2 Hardware Description

Describes the physical structure and components of the PM-9000 Express patient monitor.

2.3 Software Description

Explains the system software architecture, including its functions and tasks.

2.4 System Parameters and Principles

Discusses system parameters and the operational principles of various monitoring modules.

Chapter 3 Product Specifications

3.1 Safety Classifications

Details the safety classifications for electric shock, ignition, and water ingress.

3.2 Environmental Specifications

Lists the operating and storage temperature, humidity, and altitude ranges.

3.3 Power Source Specifications

Provides specifications for AC mains input and internal battery types.

3.4 Hardware Specifications

Details physical dimensions, display, recorder, indicators, and controls.

3.8 ECG Specifications

Specifies the technical parameters for Electrocardiogram (ECG) measurements.

3.10 SpO2 Specifications

Details the measurement range, resolution, and precision for SpO2.

3.15 CO2 Specifications

Provides detailed specifications for Carbon Dioxide (CO2) measurement.

3.16 AG Specifications

Details the specifications for Anesthetic Gas (AG) measurements.

Chapter 4 Disassembling;Assembling & Troubleshooting

4.1 PM-9000 Express Disassembling;Assembling

Provides procedures and diagrams for disassembling and assembling the PM-9000 Express.

4.2 Troubleshooting

Guides users through diagnosing and resolving common issues with the patient monitor.

Chapter 5 Test and Material List

5.1 Test Procedure

Details the step-by-step procedures for testing various functions and modules.

5.2 NIBP Calibration

Describes the calibration method for the Non-Invasive Blood Pressure module.

5.3 IBP CALIBRATE

Details the procedures for calibrating the Invasive Blood Pressure transducer.

5.4 CO2 CHECK

Outlines the procedure for checking the accuracy of the CO2 measurement module.

5.5 AG CALIBRATE

Provides steps for calibrating the Anesthetic Gas (AG) measurement module.

5.6 PM-9000 Express Material List

Lists the materials and part codes required for the PM-9000 Express.

Chapter 6 Maintenance and Cleaning

6.1 Maintenance

Covers pre-use checks, regular checking, and general maintenance guidelines.

6.2 Cleaning

Provides instructions on how to clean the patient monitor and its probes.

6.3 Cleaning Reagent

Lists recommended cleaning agents for the patient monitor.

6.4 Sterilization

Outlines recommended procedures and agents for sterilizing the patient monitor.

6.5 Disinfection

Provides recommendations and restrictions for disinfecting the patient monitor.

Shenzhen PM-9000 Express Specifications

General IconGeneral
CategoryPatient Monitor
ModelPM-9000 Express
ManufacturerShenzhen Mindray Bio-Medical Electronics Co., Ltd.
Display TypeTFT LCD
ECGYes
SpO2Yes
NIBPYes
RespirationYes
TemperatureYes
Pulse RateYes
Display Size12.1 inches
ParametersECG, SpO2, NIBP, Respiration, Temperature, Pulse Rate
Power SupplyAC 100-240V, 50/60Hz