EasyManua.ls Logo

Shining KF-50GW - The Flow Chart of Faults Diagnoses.; Nomal Resistance of Indoor Coil Temp Sensor.

Default Icon
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
37
Room temp,indoor coil sensor,R25=5KΩ,B25/50=3470K
Resistance(kΩ)
Temp
26
28
30
32
34
36
38
40
42
44
46
48
50
52
54
56
58
60
4.811
4.458
4.134
3.837
3.564
3.313
3.083
2.870
2.675
2.494
2.328
2.174
2.032
1.901
1.779
1.666
1.562
1.465
Nomal resistance of indoor coil temp sensor.
Temp Resistance(kΩ)
-10
-8
-6
-4
-2
0
2
4
6
8
10
12
14
16
18
20
22
24
22.40
20.38
18.56
16.93
15.45
14.12
12.92
11.84
10.85
9.962
9.153
8.418
7.749
7.141
6.587
6.081
5.619
5.197
25 5.000
The ow chart of faults diagnoses.
Faults & self-diagnoses
Connect the conne
-cting clamp
Repair the welding
face
The connecting clamp
sensor fall o
The coppor foil in welding face of
connecting clamping fall o
Conrm the connection of
sensor
fall o?
Check the resistance
is normal or not
Yes
No
Yes
No
Room temp sensor default
Indoor coil temp sensor default
Sensor short or
open circuit
PCB fault
Change the sensor
Change the PCB

Related product manuals