MANUAL No. 6G14-082 Rev.2
Published in Mar. 2015
Revised in Mar. 2015
MODEL CV-86 SERIES
PIEZOELECTRIC VELOCITY TRANSDUCER
INSTRUCTION MANUAL
Question and Answer IconNeed help?

Do you have a question about the Shinkawa CV-86 Series and is the answer not in the manual?

Shinkawa CV-86 Series Specifications

General IconGeneral
BrandShinkawa
ModelCV-86 Series
CategoryTransducer
LanguageEnglish

Summary

FOREWORD

Safety Precautions

Important safety warnings and precautions to prevent damage or injury during use and installation.

Before Use Inspection and Storage

Instructions for inspecting the unit for damage and proper storage conditions before initial use.

GENERAL INFORMATION

General Overview

Overview of the Model CV-86 Series Piezoelectric Velocity Transducer and its applications.

System Configuration Example

Illustrates a typical system setup for the CV-86 transducer with monitoring devices.

SPECIFICATIONS

Model and Cable Configurations

Overview of CV-861/EX and CV-862/EX models, including standard, drip-proof, and integral cable types.

Key Performance Specifications

Detailed technical parameters such as sensitivity, frequency response, vibration limits, and protection ratings.

RECEIVING INSPECTION AND STORING

Receiving Inspection

Procedure for visually inspecting the transducer for shipping damage upon receipt.

Storing Considerations

Guidelines for temporarily storing the transducers, including prohibited locations and conditions.

INSTALLATION

General Mounting Information

General information on mounting the CV-86 transducer using the attached mounting stud.

Installation Procedure

Step-by-step instructions for drilling, cleaning, and securing the transducer during installation.

Connector Connection Procedure

Steps for securely connecting the transducer's connector and preventing loosening due to vibration.

Cabling Guidelines

Guidelines for cabling, including cable type, length limits, routing, and bend radius.

WIRING DIAGRAM

Wiring Procedure and Diagrams

Instructions for wiring the CV-86 transducer, including power source requirements and typical wiring diagrams.

MAINTENANCE

Maintenance Checks

Periodic checks to ensure satisfactory operation, including transducer mounting and cable connections.

INTRINSIC SAFETY

TIIS Intrinsic Safety Certification (Japanese)

Intrinsic safety information for TIIS certification, including circuit diagrams and parameters (Japanese).

NEPSI Intrinsic Safety Certification (Chinese)

Intrinsic safety certificate details from NEPSI, including model, explosion marking, and parameters (Chinese).

NEPSI Explosion Protection Certificate

Details of the explosion protection certificate issued by NEPSI, including parameters and validity.

KTL Intrinsic Safety Certification (Korean)

Safety certification details from KTL for CV-861 model, including product overview and usage conditions (Korean).