MANUAL NO. 29602E4.7
Published in Apr.1996
Revised in Feb.2012
VM-5 SERIES MONITOR
MODEL VM-5S DUAL TACHOMETER
INSTRUCTION MANUAL

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Shinkawa VM-5K and is the answer not in the manual?

Shinkawa VM-5K Specifications

General IconGeneral
BrandShinkawa
ModelVM-5K
CategoryMonitor
LanguageEnglish

Summary

Safety Conventions

Safe Use Guidelines

Provides critical safety instructions for grounding, wiring, handling components, and operation.

Specifications

Interconnection

Description of Functions

Parameter Setting

Accessing and Navigating Settings

Covers face plate withdrawal, internal access, key operations, and DIP switch settings.

Parameter Setting Mode 1 Configuration

Explains configuration, hierarchy, display content, and key operations for Parameter Setting 1.

Parameter Setting Mode 2 Configuration

Explains configuration, hierarchy, display content, and key operations for Parameter Setting 2.

Trigger, Hysteresis, and Target Configuration

Covers trigger level, hysteresis, target forms, and trigger mode selection for optimal detection.

Output and Relay Hysteresis Settings

Details monitor/pulse output selection and speed relay hysteresis settings.

Maintenance

Adjustment Procedures

Covers adjusting measured value span and recorder output zero and span.

Troubleshooting

Abnormal LCD Display Troubleshooting

Flowchart to diagnose and resolve issues with abnormal or blank LCD displays.

Troubleshooting Flashing OK Display

Flowchart to diagnose causes of flashing OK display, including sensor wire breakage or short-circuit.

Troubleshooting Abnormal Measured Values

Flowchart to diagnose abnormal measured values, checking trigger, hysteresis, and noise.

Troubleshooting Speed Relay Non-Operation

Flowchart to diagnose why the speed relay is not operating, checking bypass and measurement ranges.

Troubleshooting Other Issues

Flowcharts for erroneous speed relay operation, OK alarm non-operation, and no recorder output.

Site Inspection