After the trigger
The unit will attempt to recover from a momentary
disconnection of an intermittent
connector or
temporary distortion of cable. For example, if a truck
runs over the cable and the cable later recovers.
o After a trigger event is detected the unit will check
10 seconds after the data has been saved to see if
the cable has returned to its original length.
o If this is the case it will reset itself and wait for a
further trigger event.
Shut Down procedure
After the above conditions have been checked the unit
will enter a 15 minute “wait for Bluetooth
communication” period.
The button will flash briefly RED once every 30 seconds.
If during this period, a Bluetooth connection is made
the unit will connect to the application.
The data just recorded can be downloaded if required.
If no communications have been received in 15 minutes
the unit switches itself off.
Pressing the ON/OFF button for 2 seconds until button
illuminates BLUE will switch the unit of in this wait