4
32CH DMX512 Constant Voltage Decoder32CH DMX512 Constant Voltage Decoder
2
1、Brief Introduction
2、Specifications
32CH DMX512 Constant Voltage Decoder
UserManual
Model
Input voltage
Max load current
Max output power
Output scale level
Input signal
Output DMX channel
Output frequency
Decode channel
DMX512 socket
Control mode
Dimension
Weight (G.W)
32CH DMX512 Decoder
DC5V-24V
,Max 96A
3A×32CH
480W(5V)/1152W(12V)/2304W(24V)
256 levels(8bit)/65536 levels(16bit)
DMX512/RDM
Constant Voltage PWM×32CH
1K
、
2
K、4K、8K selectable
32CH
XLR-3R/ RJ45/ Terminal block
DIM /CT /RGB /RGBW 4 modes switch
L195 X W145 X H38(mm)
810g
3、Basic Features
(Please read through this manual carefully before use)
1
32CH DMX512 Constant Voltage Decoder32CH DMX512 Constant Voltage Decoder
6、Conjunction Diagram
1. Connect to DMX system:
4、Safety warnings
5、Interfaces
Welcome to use the DMX512 Constant Voltage Decoder, designed for Hi-power multiple channels
application, which is developed only for constant voltage LED lamps. It adopts advanced micro-
computer control technology to transfer DMX512/1990 signal to PWM signal. 32 channels output,
Max. 3A each channel, up to 2304W output power, 65536 gray scales, workable for single color, color
temperature, RGB and RGBW led lamp.
5
32CH DMX512 Constant Voltage Decoder
3
6
32CH DMX512 Constant Voltage Decoder
8、After-Sales
From the day you purchase our products within 3 years, if being used properly in accordance
with the instruction, and quality problems occur, we provide free repair or replacement services
except the following cases:
1.Any defects caused by wrong operations.
2.Any damages caused by inappropriate power supply or abnormal voltage.
3.Any damages caused by unauthorized removal, maintenance, modifying circuit, incorrect
connections and replacing chips.
4.Any damages due to transportation, breaking, flooded water after the purchase.
5.Any damages caused by earthquake, fire, flood, lightning strike etc force majeure of natural
disasters.
6.Any damages caused by negligence, inappropriate storing at high temperature
and humidity environment or near harmful chemicals.
7.Product has been updated.
9、Kindly Reminder
Power source must be DC constant voltage type of power supply. Due to the efficient output in some
power supplies are only 80% of total, so please select at least 20% higher output power supply than
the consumption of LED lights.
Power Source Selection:
Update Time: 2019.4.10
Gamma
value
DMXValue
Output
brightness
0
100%
2.5
3.5
6.5
1.0
0.8
0.9
<1
>1
1.5
255
1. Easy operation with OLED screen and touch buttons.
2. 8bit (256 levels)/16bit (65536 levels) grey level optional.
3. Support 3 kinds of DMX ports with signal isolation function:
3-pin XLR, RJ45
and green terminal (with signal amplifier function).
4. With the operations can be
RDM master console, such as parameters
setting, equipment recognition, etc.
RDM remote management protocol,
completed via the
browsing & setting, DMX address
5. Optional for standard, linear, LOG or custom 0.1-9.9 dimming curve.
6. Power-off data saved function.
Please don’t install this controller in lightening, intense magnetic and high-voltage fields.
1.To reduce the risk of component damage and fire caused by short circuit, make sure correct
connection.
2.Always be sure to mount this unit in an area that will allow proper ventilation to ensure a fitting
temperature.
3.Check if the voltage and power adapter suit the controller
(please select DC12-24V power supply with constant voltage)
4.Don’t connect cables with power on; make sure a correct connection and no short circuit checked
with instrument before power on.
5.Please don’t open controller cover and operate if problems occur.
The manual is only suitable for this model; any update is subject to change without prior notice.
use of
6.When the signal line is long or the wire quality causes the signal recoil effect to affect the
each signal line to
product, you can try to connect 0.25W 90-120Ω terminating resistor at the end of
solve.
Inp ut:5 V-2 4VDCInp ut:5 V-2 4VDC
I(o ut) : 3A×32C H Max 9 6AI(o ut) : 3A×32C H Max 9 6A
P(o ut) :(0~ 15. ..72 W)×32 CHP(o ut) :(0~ 15. ..72 W)×32 CH
Inp ut:5 V-2 4VDC
I(o ut) : 3A×32C H Max 9 6A
P(o ut) :(0~ 15. ..72 W)×32 CH
32 Cha nnel 8/16B its 32 Cha nnel 8/16B its
Phot oelec tric Is olati onPhot oelec tric Is olati on
32 Cha nnel 8/16B its
Phot oelec tric Is olati on
V+
V+V+
R
RR
G
GG
B
BB
W
WW
DC1 MAX 24A
DC1 MAX 24ADC1 MAX 24A
V+
V+V+
R
RR
G
GG
CH
CHCH
1
11
2
22
3
33
4
44
CH
CHCH
5
55
6
66
G
GG
B
BB
W
WW
DC4 MAX 24A
DC4 MAX 24ADC4 MAX 24A
V+
V+V+
R
RR
G
GG
B
BB
W
WW
27
2727
28
2828
CH
CHCH
29
2929
30
3030
31
3131
32
3232
DC4
DC4DC4
DC3
DC3DC3
DC3
DC3DC3
DC4
DC4DC4
+
++
-
--
+
++
-
--
POW ER INPOW ER INPOW ER IN
DC2
DC2DC2
DC1
DC1DC1
DC1
DC1DC1
DC2
DC2DC2
-
--
+
++
-
--
+
++
1: DATA+ 2:DATA- 7&8: GND1: DATA+ 2:DATA- 7&8: GND1: DATA+ 2:DATA- 7&8: GND
RDM/DMXINRDM/DMXINRDM/DMXIN RDM/DMX OUTRDM/DMXOUTRDM/DMXOUT
1 . . .. . . 8
1 . . .. . . 81 . . .. . . 8
1 . . .. . . 8
1 . . .. . . 81 . . .. . . 8
POW ER INPOW ER INPOW ER IN
DMX51 2 DE CODERDMX51 2 DE CODERDMX51 2 DE CODER
MMM
+++
---
B
BB
W
WW
7
77
8
88
V+
V+V+
R
RR
G
GG
B
BB
W
WW
DC2 MAX 24A
DC2 MAX 24ADC2 MAX 24A
V+
V+V+
R
RR
G
GG
B
BB
W
WW
CH
CHCH
9
99
10
1010
11
1111
12
1212
CH
CHCH
13
1313
14
1414
15
1515
16
1616
V+
V+V+
R
RR
G
GG
B
BB
W
WW
DC3 MAX 24A
DC3 MAX 24ADC3 MAX 24A
V+
V+V+
R
RR
G
GG
B
BB
W
WW
CH
CHCH
17
1717
18
1818
19
1919
20
2020
CH
CHCH
21
2121
22
2222
23
2323
24
2424
V+
V+V+
R
RR
CH
CHCH
25
2525
26
2626
1
11
2
22
3
33
RDM/DMX OUT
RDM/DMX OUTRDM/DMX OUT
2
22
1
11
3
33
RDM/DMX IN
RDM/DMX INRDM/DMX IN
1: GND
1: GND
2: DATA-
2: DATA-
3: DATA+
3: DATA+
1: GND
2: DATA-
3: DATA+
DMXAMP
DMXAMPDMXAMP
RDM/DMXIN
RDM/DMXINRDM/DMXIN
D
DD
+
++
-
--
GND
GNDGND
D
DD
D
DD
+
++
-
--
GND
GNDGND
D
DD
POWERDC1~DC4
POWERDC1~DC4POWERDC1~DC4
5.5-7.5mm wire prep.
5.5-7.5mm wire prep.5.5-7.5mm wire prep.
2.5-4.0/13-10AWG
2.5-4.0/13-10AWG2.5-4.0/13-10AWG
OUTPUTCH1~CH32
OUTPUTCH1~CH32OUTPUTCH1~CH32
5.5-7.5mm wire prep.
5.5-7.5mm wire prep.5.5-7.5mm wire prep.
1.5-2.5/16-12AWG
1.5-2.5/16-12AWG1.5-2.5/16-12AWG
RDM
RDMRDM
DMX
DMXDMX
195mm
145mm
145mm
38mm
RJ45
3-pinXLR
Main component description:
OLED screen
Green terminals
With signal
amplifier function
Power input
Power input
Green terminals
LED lamps connection
DMX OU T
DMX IN
DMX OU T
DC12
-
24
V
LED
LEDLEDLEDLED
LED LED LED
LED
LEDLEDLE DLED
LED LED LED
DMX IN
PowerSupply
7、Operating instructions
Modes
Description
Brightness adjustable
M0
NO
M1
M2
M3
M4
M5
M6
M7
M8
M9
M10
RGBW can be dimmed separately in static mode
Brightness, speed adjustable
All mode cycle
3 color skipping
7 color skipping
White color strobe
3 color smooth
Full color smooth
RG color smooth
R B color smooth
GB color smooth
White color fade & change
Great cycle
Brightness, speed adjustable
Brightness, speed adjustable
Brightness, speed adjustable
Brightness, speed adjustable
Brightness, speed adjustable
Brightness, speed adjustable
Brightness, speed adjustable
Brightness, speed adjustable
6. Instruction:
a) 8 outputs controlled synchronously when in test mode.
b) Test mode as below:
DC5-2 4V
DC
5
-
2
4
V
DC5
-
24
V
DC
5-2
4
V
PowerSupply
PowerSupply
PowerSupply
PowerSupply
DMX Bit : 8
Output Freq : 1.0K
Output Mode : RGBW
DMX Addr : 001
DMX Bit : 8
DMX Addr : 001
DMX Bit : 8
Output Freq :1.0K
Output Mode : RGBW
DMX Addr : 001
Output Freq :1.0K
Output Mode : RGBW
DMX Addr : 001
Output Freq : 1.0K
Output Mode : RGBW
DMX Bit : 8
Output Curve: 1.0
Enter Test Mode
Address setting table
DIM DIM
CT CT RGB RGB RGBW RGBW
ChannelChannel
8
1616
32
24
48
32 64
8bit 16bit8bit 16bit8bit 16bit8bit 16bit
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
001 001 001 001
004 007
010 013
001
002 002 002
004 008
011 014
001 001
003 003
004
007
012 015
001
002 001 004
004
008
010 016
002 003 004 005
005 009
013 017
002 004 005 006
005
010 014 018
002 003 006 007
005 009
015 019
002 004 004 008
005
010 013
020
003 005 007 009
006
011 016 021
003 006 008
010
006
012 017
022
003 005 009
011
003 006 007
012
Address
Quantity
Address
Quantity
Resolution Resolution
Mode Mode
001
002
001
002
001
002
001
002
001
002
005
006
001
002
005
006
005
006
005
006
005
006
005
006
005
006
007
008
007
008
007
008
007
008
009
010
009
010
009
010
009
010
011
012
011
012
011
012
007
008
013
014
013
014
015
016
015
016
017
018
017
018
019
020
021
022
023
024
013
014
011
012
005
006
001
002
003
004
003
004
003
004
003
004
003
004
003
004
003
004
003
004
001
002
001
002
007
008
007
008
013
014
015
016
019
020
021
022
025
026
027
028
013
014
015
016
023
024
019
020
029
030
031
032
007
008
007
008
009
010
009
010
009
010
009
010
011
012
011
012
017
018
017
018
025
026
027
028
029
030
025
026
031
032
033
034
033
034
035
036
037
038
039
040
041
042
043
044
019
020
019
020
021
022
023
024
23
24
25
26
27
28
29
30
31
32
23
24
25
26
27
28
29
30
31
32
007
013 019
025
007
014
020 026
007
013 021
027
007
014 019
028
008
015
022 029
008
016
023 030
008
015
024
031
008
016
022 032
006
011 018
023
006
012 016
024
011
012
011
012
035
036
045
046
047
048
031
032
021
022
023
024
013
014
013
014
015
016
015
016
015
016
015
016
025
026
027
028
029
030
029
030
031
032
031
032
041
042
037
038
043
044
045
046
053
054
047
048
055
056
057
058
059
060
061
062
063
064
043
044
013
014
027
028
039
040
051
052
013
014
025
026
037
038
049
050
DMX IN
DMX OU T
DMX IN
LED
LEDLEDLEDLED
DC
5-
24V
DC
5
-
24V
LED LED L ED
LED
LEDLEDLEDLED
D
C5
-2
4
V
D
C
5-24V
LED LED L ED
DMX OUT
PowerSupply
PowerSupply
PowerSupply
PowerSupply
OLED screen interface:
2. DMX address setting
Press “+" or “-" key to set
DMX address.
Range: 001~512
Main page
3. PWM frequency
8K、4K、2K、1K
It is recommended to use 1K
Press “+" or “-" key to choose.
Optional :
Press “+" or “-" key to choose.
Optional :
DIM、CT、RGB、RGBW
4. Mode
5. Grey scale
Press “+" or “-" key to choose.
Optional : 8bit
16bit
(choose it if the master
controller support this function)
6. Dimming curve
Press “+" or “-" key to choose.
Optional : 0.1~9.9 (only 8bit can
be set)
It is recommended to use 1.8
0.1-9.9 is for special requirements.
2. Work with RDM controller:
1. Lock screen interface:
No operation after 10 seconds
into the lock screen interface,
display only has set up a good
parameter, long press the M
key for 2 seconds to unlock.
The star symbol flashes when
there is DMX signal in.
7.Built-in test
R: 000 G: 000
B: 000 W: 000
Curve: 1.8 Exit
Mode: M0 bit8
Press “+" or “-" key to choose.
Optional: Mode M0-10
Digits 8bit or 16bit
Grey scale 0-255 or 0-65536
Gamma value 0.1-9.9(only 8bit
can be set)
Note: RDM controller can only be used normally with 3-pin XLR terminals.
A:001B:8F:1.0
M:RGBWC:1.8 *
DecodeMode,Long
press'M'unlock
Press "M" key, switch entries.
Press "+" or “-" key, parameter adjustment.
Exit: back to previous page.
Long press three buttons in case of
power off.
Restar to restore the factory settings.