If the microphone still does not work, contact Shure Application Engineering at 1-800-516-2525. Please have the
camcorder user's guide available.
Wiring Diagram
Frequency Response
20 to 20,000Hz± 2dB
Impedance
Low Impedance 600 Ω (supplied) or 150 Ω
Medium impedance 2,500 Ω
DC Resistance
Low Impedance 600 Ω winding 56 Ω
150 Ω winding 28 Ω
Medium impedance Open circuit
Voltage Ratio
Low Impedance to Medium impedance
600 Ω +6dB
150 Ω +12dB