The device triggers alarms as soon as the set threshold (consisting of “Measurement
Alarm” 1/2 “Threshold”) is exceeded in the read process.
The device can use the following value as a source for the alarm:
•
RSSI value (transponder in the detection range)
The “Time the transponder is in the detection range [ms]” specifies for how many ms
the transponder is in the detection range. If this time is less than the set threshold, the
device outputs an alarm.
The triggered alarm remains active in mode "2 = RSSI" until the condition is fulfilled
again. If the “Transponder in Range time” condition was selected, the alarm is active
until a new transponder is situated in the detection range.
Index dec
(hex)
Name Format
(Offset)
Lenght Access
1)
Default
Value
Value / Range Remark [Unit]
71 (0x47) Alarm Record 12 Byte rw
1 (0x01) Alarm 1 configuration Bit (88) 8 Bit rw 0 0 = Always off
1 = Active
2 (0x02) Alarm 1 threshold Bit (56) 32 Bit rw 0 Alarm 1 goes
true if Alarm 1
reference
value ≥ Alarm
1 threshold
3 (0x03) Alarm 1 comparative
value
Bit (48) 8 Bit rw 2 0 = SIO CNT Q1
1 = SIO CNT Q2
2 = RSSI
3 = Transponder
IN range time [ms]
4 (0x04) Alarm 2 Configuration Bit (40) 8 Bit rw 0 0 = Always off
1 = Active
5 (0x05) Alarm 2 threshold Bit (8) 32 Bit rw 0 Alarm 2 goes
true if Alarm 2
reference
value ≥ Alarm
2 threshold
6 (0x06) Alarm 2 comparative
value
Bit (0) 8 Bit rw 2 0 = SIO CNT Q1
1 = SIO CNT Q2
2 = RSSI
3 = Transponder
IN range time [ms]
1)
ro = read only, wo = write only, rw = read/write
2)
Subindex access not supported
Device Characteristics
Specific information about the device properties:
Index dec
(hex)
Name Format
(Offset)
Lenght Access
1)
Default
Value
Value /
Range
Remark [Unit]
73 (0x49) Device characteristics Record
2)
144Byte ro Features of the
device
1 (0x01) RFID standard compati‐
bility
Bit (896) 32Byte ro 13.56
MHz,
ISO15693
8 OPERATION
46
O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309/1KDE/2023-12-19 | SICK
Subject to change without notice