(hex)
Name Format
(Offset)
Lenght Access
1)
Default
Value
Value /
Range
Remark [Unit]
2 (0x02) Read-write distance
max
Bit (640) 32Byte ro 60mm
with diam
50mm
SLIX tag
3 (0x03) Supply voltage range U
b
Bit (512) 16Byte ro DC 11 V ...
32 V
4 (0x04) Max. output current Bit (384) 16Byte ro ≤ 200 mA
5 (0x05) Ambient operating tem‐
perature
Bit (256) 16Byte ro –25 °C ...
+80 °C
6 (0x06) Storage temperature Bit (128) 16Byte ro –25 °C ...
+80 °C
7 (0x07) Enclosure rating Bit (0) 16Byte ro IP67
1)
ro = read only, wo = write only, rw = read/write
2)
Subindex access not supported
3)
U
b
= V
S
(Power supppy voltage)
Tag Timing
In the Tag timing tab, the time of entry and exit as well as the resulting duration of the
time of the last transponder in the detection range of the device are calculated.
Index dec
(hex)
Name Format
(Offset)
Lenght Access
1)
Default
Value
Value /
Range
Remark [Unit]
74 (0x4A) Transponder time
monitoring
Record 24 Byte ro System time of a trans‐
ponder event
1 (0x01) System time IN Bit (128) 64 Bit ro System time stamp trans‐
ponder entering reading field
of device [ms]
2 (0x02) System time OUT Bit (64) 64 Bit ro System time stamp trans‐
ponder leaving reading field
of device [ms]
3 (0x03) Transponder IN
RANGE time
Bit (0) 64 Bit ro IN RANGE = System Time
OUT minus System Time IN
[ms]
1)
ro = read only, wo = write only, rw = read/write
2)
Subindex access not supported
Diagnostics
Index dec
(hex)
Name Format
(Offset)
Lenght Access
1)
Default
Value
Value /
Range
Remark [Unit]
89 (0x59) Transponder time
monitoring
Record
2)
24 Byte ro Diagnostic
1 (0x01) Operating time Bit (128) 64 Bit ro Reset upon power-cycle or
standard command Device
Reset [ms]
2 (0x02) Error counter Bit (96) 32 Bit ro Errors since last startup /
reset
3 (0x03) RFU Bit (64) 32 Bit ro
4 (0x04) RFU Bit (32) 32 Bit ro