Used for displaying Setpoint and changing it. Also used for parameter programming.
Used for increasing values during Setpoint and parameter changes, and manual defrost activation.
Indicates when the compressor relay is active.
Indicates Setpoint display/programming and blinks during parameter programming.
Indicates automatic or manual defrost status.
Signals alarm conditions and blinks when silenced.
Setpoint intervention differential for compressor control.
Minimum value that can be assigned to the Setpoint.
Maximum value that can be assigned to the Setpoint.
Defines the defrost type: electric defrost or cycle inversion defrost.
Sets the defrost interval in hours or minutes.
Determines how the defrost interval is counted (e.g., DIGIFROST or real time).
Sets a delay time in minutes before defrost starts.
Defines the maximum duration for the defrost cycle in minutes.
Sets the temperature at which defrost for the first evaporator ends.
Stops fans when the temperature measured by the defrost probe exceeds a set value.
Sets a delay time in minutes for fan start after defrost.
Specifies the dripping time in minutes after defrost.
Determines if defrost is activated upon instrument startup.
Controls how the display shows temperature during defrost.
Allows selection to disable the fan during defrost.
Selects the probe used for alarm temperature monitoring.
Defines alarm temperature type as absolute or relative.
Sets the maximum temperature threshold for high alarms.
Sets the minimum temperature threshold for low alarms.
Sets the operating differential for temperature alarms.
Excludes alarms for a set period after instrument startup.
Excludes defrost alarms for a set period after defrost.
Sets a delay for temperature alarm signaling.
Enables or disables fan lock when the compressor is OFF.
Selects output state in case of faulty probe.
Defines ON/OFF times for the relay via Ont/OFt parameters.
Sets the ON time for the compressor when in duty cycle mode.
Sets the OFF time for the compressor when in duty cycle mode.
Selects protection type to prevent close compressor startups.
Sets the time delay between successive compressor starts.
Sets a delay for the activation of outputs at startup.
Selects the presence of evaporator probes.
Allows calibration of the measured value from the control probe.
Sets the defrost termination temperature for the second evaporator.
Selects the device address within a remote control network.
Selects the device family address within a remote control network.
Determines the display number format (e.g., decimal point, resolution).
Disables the keyboard to prevent unauthorized operations.
Allows setting a password to access parameter programming.
Read-only parameter showing the product's release code.
Summary of factory-set parameters that cannot be modified.