MC35i AT Command Set
8.9 AT^SHOM
s
m
obil
e
MC35i_ATC_V01.03 Page 190 of 444 5/7/04
Confidential / Released
8.9 AT^SHOM Display Homezone
Syntax
Command Description
TA returns homezone state. Result is valid only, if network registration state <stat> is 1 (registered) (see
AT+CREG).
Feature is available only for supported network operators (Viag, One2One, Orange and LCI) and requires a suit-
able SIM card. If the homezone feature is not supported by the network operator or SIM card, result is always 0.
Parameter Description
0 ME is out of Homezone
1 ME is within the Homezone
Test Command
AT^SHOM=?
Response(s)
OK
Exec Command
AT^SHOM
Response(s)
^SHOM: <homezonestate>
OK
ERROR
+CME ERROR: <err>
PIN ASC0 MUX1 MUX2 MUX3
! % % % %
Reference(s)
SIEMENS
<homezonestate>
(num)