EasyManua.ls Logo

Siemens 9001042052 - User Manual

Siemens 9001042052
92 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
de Deutsch 2
en English 9
fr Français 14
nl Nederlands 20
pl Polski 25
cz Česky 32
ru Русский 38
sr Srpski 45
hr Hrvatski 51
es Español 57
pt Português 63
th
ภาษไทย 70
hk ѣᮽ 77
DH12400
DH12401
DH18400
DH21400
DH24400
DH40018
DH40021
DH40024
9001042052
Upute za montažu i uporabu
Instrucciones de instalación y de uso
Manual de instalação e serviço
คําอธบาย ชีแจ ในการ ประกอบ
ติดตง แล คําชีแจ วิธ ใช
ᆿ㻻ૂֵ⭞䈪᱄Ҝ
Montage- und
Gebrauchsanleitung
Installation and
operating instructions
Notice de montage
et d’utilisation
Montage- en
gebruikshandleiding
Instrukcja montażu
i użytkowania
Návod pro montáž
a návod k použití
Инструкция по монтажу
и эксплуатации
Uputstvo za montažu
i upotrebu
Question and Answer IconNeed help?

Do you have a question about the Siemens 9001042052 and is the answer not in the manual?

Overview

This document provides installation and operating instructions for a Siemens continuous-flow heater, a Class I appliance designed for domestic and household-based, non-commercial applications. It is suitable for use in various settings such as employee catering facilities, offices, agricultural operations, guest houses, small hotels, and similar residential establishments. The appliance must be permanently connected to installed pipes, and the conductor cross-section must comply with the installed appliance power. It is suitable for connection to DVGW-tested plastic pipes and must only be installed in a frost-free room.

Function Description

The continuous-flow heater is designed to provide hot water on demand. It operates by heating water as it flows through the unit. The device offers two heating settings: "Economy setting e" for reduced power and "Intensive setting II" for full power. The specific power output varies by model, ranging from 12 kW to 24 kW, and is compatible with rated voltages of 220 V3~, 230 V3~, 380 V3~, and 400 V3~.

The appliance features a control knob for selecting the desired temperature or power setting. It is equipped with safety mechanisms, including an automatic circuit breaker that activates in case of malfunction or leakage. In such events, the power supply must be disconnected, and the cold water supply to the appliance must be shut off. Repairs should only be performed by factory service or an authorized service agent.

Important Technical Specifications

The continuous-flow heater models covered by this manual include DH12400, DH12401, DH18400, DH21400, DH24400, DH40018, DH40021, and DH40024.

  • Rated Power [kW]: Available in 12, 13.2, 18, 21, and 24 kW.
  • Rated Voltage: Supports 220 V3~, 230 V3~, 380 V3~, and 400 V3~.
  • Economy Setting e [kW]:
    • 1st stage: Not applicable for 12/13.2 kW models; 6 kW (18 kW model), 7 kW (21 kW model), 8 kW (24 kW model).
    • 2nd stage: 8 kW (12/13.2 kW models), 8.8 kW (12/13.2 kW models), 12 kW (18 kW model), 14 kW (21 kW model), 16 kW (24 kW model).
  • Intensive Setting II [kW]:
    • 1st stage: Not applicable for 12/13.2 kW models; 9 kW (18 kW model), 10.5 kW (21 kW model), 12 kW (24 kW model).
    • 2nd stage: 12 kW (12/13.2 kW models), 13.2 kW (12/13.2 kW models), 18 kW (18 kW model), 21 kW (21 kW model), 24 kW (24 kW model).
  • Switch-on Point [l/min]:
    • 1st stage: Not applicable for 12/13.2 kW models; 4.0 l/min (18 kW model), 4.5 l/min (21 kW model), 5.0 l/min (24 kW model).
    • 2nd stage: 3.6 l/min (12/13.2 kW models), 5.0 l/min (18 kW model), 5.8 l/min (21 kW model), 6.6 l/min (24 kW model).
  • Mixed Water [l/min] at Rated Power (supply temperature 12 °C):
    • Approx. 38 °C: 6.6 l/min (12 kW), 7.3 l/min (13.2 kW), 9.9 l/min (18 kW), 11.6 l/min (21 kW), 13.2 l/min (24 kW).
    • Approx. 50 °C: 4.5 l/min (12 kW), 5.0 l/min (13.2 kW), 6.8 l/min (18 kW), 7.9 l/min (21 kW), 9.1 l/min (24 kW).
  • Minimum Flow Pressure of Appliance [MPa (bar)]:
    • With flow limiter: 0.03 (0.3) MPa (12/13.2 kW), 0.07 (0.7) MPa (18 kW), 0.08 (0.8) MPa (21 kW), 0.09 (0.9) MPa (24 kW).
    • Without flow limiter: 0.02 (0.2) MPa (12/13.2 kW), 0.04 (0.4) MPa (18 kW), 0.05 (0.5) MPa (21 kW), 0.06 (0.6) MPa (24 kW).
  • Application Area in Water Specific Electric Resistance at 15 °C [Ωcm]: ≥800 (12/13.2 kW), ≥1300 (18/21/24 kW).
  • Rated Pressure [MPa (bar)]: 1 (10) MPa for all models.
  • Maximum Permissible Supply Temperature [°C]: 20 °C for all models.

Usage Features

The continuous-flow heater is designed for ease of use. To increase water temperature, the warm water tap should be opened slightly. To decrease water temperature, the cold water tap should be opened.

The "e" setting is ideal for washbasins, showers, and bidets. The "II" setting is used in combination with a thermostatically-controlled mixer for high temperatures or large volumes of water, suitable for dishwashing, cleaning, and bath tubs.

In case of low water pressure, if the appliance does not reach full power, the flow limiter (if installed) can be removed. This is detailed in the "Additional Information" section of the manual.

For combination with electric storage heaters, a priority switch (load shedding relay) BZ 45L21 can be used. A pipe set BZ 45U20 is available for under-sink installation, and a mounting set BZ 45K23 is available for surface-mount installation.

Maintenance Features

Regular cleaning of the appliance is recommended using a damp cloth. Abrasive or aggressive cleaning detergents should not be used. The manual explicitly states not to use a steam cleaner.

The appliance does not typically require descaling, but if hard water causes limescale deposits, a service agent should be contacted.

In winter, if the desired water temperature is not reached due to low inlet temperatures, the warm water tap should be opened fully, and the cold water tap should be reduced to compensate and achieve the desired temperature.

The manual also provides a troubleshooting guide for common issues such as low water flow, insufficient hot water, or the appliance not switching on. These issues often relate to clogged filters or valves, or electrical supply problems, and solutions range from cleaning components to contacting a specialist.

The device is marked in accordance with European Directive 2012/19/EU on waste electrical and electronic equipment (WEEE), indicating that it should not be disposed of with household waste. Information on proper disposal methods can be obtained from local authorities or retailers.