13
en
Technical data
Type
DO05705M
Undersink
DO3170D5M
DO05705CHM
Undersink
DO05805M
Over-sink
DO05805CHM
Over-sink
Rated output [kW] 2.2 1.8 2.2 1.8
Rated capacity [l] 5.0 5.0 5.0 5.0
CLICKFIX plus installation technology ✓✓✓✓
Pressure stop ✓✓––
Drip stop ✓✓––
Mixed water quantities 40 °C
(15 °C/85 °C) / (15 °C/85 °C) [l] 9.5/14 9.5/14 9.5/14 9.5/14
Variable temperature adjustment up to [°C] 85 85 85 85
Stand-by power consumption
at 65 °C/24 h [kWh/d] 0.18 0.18 0.18 0.18
Electrical connection [V] 230 230 230 230
Heat-up time to 60 °C
(supply temperature 12 °C) [min] 8989
Fuse protection [A] 10 10 10 10
Water connection ["] 3/8 3/8 1/2 1/2
Maximum flow [l/min] 5555
Cable length [m] 0.6 0.6 0.6 0.6
Dimensions (Height x Width x Depth) [mm] 435 x 270 x 240 435 x 270 x 240 435 x 270 x 240 435 x 270 x 240
Weight, filled [kg] 7.7 7.7 7.7 7.7
Energy efficiency class
AAAA
Load profile
XXS XXS XXS XXS
Annual energy consumption
[kWh] 477 484 481 484
Daily energy consumption
[kWh] 2.260 2.340 2.310 2.340
Sound power level
[dB] 15 15 15 15
Hot water heating energy efficiency
[%] 37.8 36.8 37.2 36.8