Security recommendations
SCALANCE M874, M876
12 Operating Instructions, 08/2018, C79000-G8976-C331-08
Factory setting
Open
The factory setting of the port is "Open".
Closed
The factory setting of the port is "Closed".
Authentication
Specifies whether or not the protocol is authenticated during access.
Protocol
Protocol/port
number
Port status
Default port status
Authentication
Encryption
Local access
External
access
SSH
SFTP
TCP/22 Open
(when configured)
Open Closed Yes Yes
HTTP
TCP/80 Open
(when configured)
Open Closed Yes No
HTTPS
TCP/443 Open Open Closed Yes Yes
SNTP
UDP/123 Open
(only outgoing)
Closed Closed No No
SNMP v1/v3
UDP/161 Open
(when configured)
Open Closed Yes Yes (when con-
figured)
DNS server
TCP/53 Open
(when configured)
Open Closed No No
DNS client
UDP/53 Open
(when configured)
Open Closed No No
Syslog
UDP/514 Open
(only outgoing)
Closed Closed No No
IPsec/IKE
UDP/500
UDP/4500
Open
(when configured)
Closed Open Yes Yes
DHCP server
UDP/67
Open
(when configured)
Open Closed No No
DHCP Client
UDP/68 Open
(when configured)
Open Closed No No
NTP client
UDP/123 Open
(only outgoing)
Closed Closed No No
NTP server
UDP/123
Open
Closed
Closed
No
No
Siemens Remote
Service
(cRSP/SRS)
TCP/443 Open
(only outgoing)
Closed Closed Yes Yes
PROFINET
UDP/34964
Open
Open
Open
No
No
OpenVPN to
SINEMA RC
TCP, UDP
depending
on server
config [only
with Key-
Plug]
Open
(only outgoing)
Closed Closed Yes Yes